Capability of 1,3 µm SWIR radiation detection using commercial CCD cameras was verified in a set of measurements with various sources and detectors. In spite of a very small sensitivity of silicon CCD cameras at 1,3 µm, in experiment was proofed that selected CCDs are able to detect reliably this radiation and they are suitable for visualization and measurement of SWIR laser beams with a sufficient intensity. Simultaneously, fundamental properties of detectors and their working limits in SWIR band were investigated. In terms of resolution, used detectors were superior to SWIR detectors available for comparison. An industrial megapixel CCD camera with a GEVision interface was modified for SWIR laser beam measurement at wavelength 1,3 µm with a high resolution. The camera was tested with a continual diode laser at 1310 nm and a Nd:YAG laser on a secondary laser transition at 1321 nm and with a pulsed iodine photo - dissociative laser at 1315 nm with a resolution of 1390 x 1040 points. and Schopnost detekce 1,3 µm SWIR záření pomocí komerčních křemíkových CCD kamer byla ověřena řadou měření s různými zdroji a detektory. Bylo experimentálně prokázáno, že vybrané křemíkové CCD kamery jsou i vzhledem k extrémně malé citlivosti na 1,3 µm schopny spolehlivě detekovat toto záření a jsou vhodné pro vizualizaci a měření SWIR laserových svazků s dostatečnou intensitou. Zároveň byly prozkoumány fundamentální vlastnosti detektorů a jejich pracovní limity v této oblasti. Rozlišovací schopnost zkoumaných detektorů několikráte převyšovala parametry dostupných SWIR detektorů. Průmyslová megapixelová CCD kamera byla modifikována pro měření laserového svazku na vlnové délce 1,3 µm s velkým rozlišením. Kamera byla testována s kontinuálním diodovým laserem na 1310 nm a Nd:YAG laserem na vedlejším laserovém přechodu 1321 nm a s impulsním jódovým fotodisociačním laserem na 1315 nm s rozlišením 1390 x 1040 bodů.
The ultra-hydrophobic surfaces have the prospect of great importance in industry, both in applications demanding easy cleaning, and they are presumed to reduce loss when the active parts of hydraulic machines are treated. Interaction of fluids with ultrahydrophobic surface is accompanied by creation of air layer, so called air film, which depends on the quality of the surface. The quality of the surface is influenced by the matrix roughness, the character of physical or chemical cover. These properties lead to monolithic air layer presented as air film, or lead to plurality of bubbles of various sizes seated upon the surface. The air film can be observed visually at sufficient magnification and the dynamic interaction between fluid flow and air film can be studied with Global Imaging methods. Here we present the visualization of air film depending on Reynolds number of flowing liquid. and Vysoce hydrofobní povrchy nacházejí své místo a uplatnění v průmyslu i mezi běžnými uživateli. Jejich aplikací na zátěžové materiály se očekává snadné čištění povrchů, např. v odpadních čistírnách a domácích zásobárnách užitkových vod. Ve strojírenském průmyslu se pak aplikují na hydraulické části okruhů, a to na jejich pasivní i aktivní části. Vysoce hydrofobní povrch zde ovlivňuje interakce kapalin v blízkosti stěn. Z prostého pozorování ponoření vysoce hydrofobního povrchu do kapaliny je zřejmé vytvoření vzduchové vrstvy mezi povrchem a kapalinou, která je označována jako vzduchový film. Kvalita a tloušťka vzduchového filmu je velmi ovlivněna kvalitou hydrofobního povrchu, ale také drsností a chemickou podstatou nosného materiálu. Narušený vzduchový film nebo film s nedostatečnou tloušťkou neeliminuje usazování nečistot na materiálu a při dynamických interakcích s kapalinami je snadno smytelný. V tomto projektu jsme se zaměřili na stanovení tloušťky vzduchového filmu v dynamické interakci s proudící kapalinou za použití techniky ''Global Imaging''.
In this article, evaluating system for measuring of near electromagnetic field is described. The field is radiated by a cell phone. Results from proposed software are presented here. It can help find positions with raised emissivity and give some indication for engineering interventions leading to elimination of interference of electronic systems. and V článku je popsán vyhodnocovací systém pro měření blízkého elektromagnetického pole vyzařovaného mobilním telefonem. Jsou zde prezentovány výsledky z navrženého vizualizačního programu, pomocí kterého lze nalézt místa se zvýšenou vyzařovací schopností a tím naznačit cestu pro konstrukční zásahy k omezení vzájemného rušení elektronických systémů.