1 - 8 of 8
Number of results to display per page
Search Results
2. Abnormální hyperbilirubinémie u pacientky s mnohočetným myelomem
- Creator:
- Šolcová, L., Friedecký, Bedřich, Radocha, Jakub, Tichý, Miloš, Maisnar, Vladimír, Holečková, Magdalena, and Vávrová, Jaroslava
- Type:
- model:article, article, Text, kazuistiky, and TEXT
- Subject:
- mnohočetný myelom--diagnóza, imunoglobuliny - kappa-řetězce--krev, bilirubin--krev, financování organizované, chybná diagnóza, klinické laboratorní techniky, hyperbilirubinémie--diagnóza, lidé, and ženské pohlaví
- Language:
- Czech and English
- Description:
- Cíl: Publikace případu falešně zvýšené koncentrace bilirubinu u pacientky s mnohočetným myelomem. Metoda: U pacientky s diagostikovaným a léčeným mnohočetným myelomem byla stanovena atypicky vysoká hodnota sérového bilirubinu diagnostickým kitem Roche na přístroji Modular a normální, o dva řády nižší hodnota téhož analytu diagnostickým kitem Olympus na přístroji Olympus 400. Výsledky: Pacientka měla v krvi koncentraci paraproteinu IgG kappa 61,6 g/l. Sérový bilirubin, stanovený na přístroji Modular měl hodnotu 546 μmol/l, zatímco při opakovaném měření na přístroji Olympus 400 byla hodnota u stejné pacientky 6 μmol/l. Nižší hodnota korespondovala s klinickým stavem pacientky. Diskuse a závěr: Oba výrobci upozorňují ve svých pracovních návodech na potenciální možnost pozitivních interferencí v přítomnosti IgM lambda. Zjistili jsme extrémní pozitivní chybu o velikosti dvou řádů v přítomnosti paraproteinu IgG kappa u jednoho z nich (Roche). Chyba je snadno detekovatelná inspekcí záznamu kinetiky reakčního průběhu a neměla by ujít pozornosti při vydávání výsledků., Objective: Falsely elevated serum bilirubin in patient with multiple myeloma. Method: We determined serum bilirubin in a patient with multiple myeloma by using Modular and we repeated analysis by using Olympus 400. Results: Concentration of IgG kappa was 61.6 g/l. Serum bilirubin value measured on the Modular Roche has been 546μmol/l, while repeated measurement on Olympus 400 provided value only 6 μmol/l. Lower Olympus value corresponded to clinical status of the patient. Discussion and conclusion: Both producers introduce in their working manual the possibility of IgM lambda interference for bilirubin measurement. We found extremely high systematic error in presence IgG kappa only in Modular Roche, not in Olympus 400. Analyzer Modular Roche gives the possibility of an easy error determination by using inspection of kinetic of reaction run., Šolcová L., Friedecký Bedřich, Radocha J., Tichý M., Maisnar V., Holečková M., Vávrová J., and Lit.: 3
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
3. Kryoglobuliny v souboru 3 392 monoklonálních imunoglobulinů
- Creator:
- Tichý, Miloš, Maisnar, Vladimír, Hrnčíř, Zbyněk, Palička, Vladimír, and Vávrová, Jaroslava
- Type:
- model:article, article, Text, and TEXT
- Subject:
- imunoglobuliny - podjednotky--analýza--izolace a purifikace, kryoglobuliny--analýza--izolace a purifikace, biologický materiál - odběr a zpracování, elektroforéza v polyakrylamidovém gelu--metody, and financování organizované
- Language:
- Czech and English
- Description:
- V práci jsou stručně uvedeny základní informace o kryoglobulinech a vlastní zkušenosti s průkazem kryoglobulinů v souboru 3392 monoklonálních imunoglobulinů. V tomto souboru bylo prokázáno 37 monoklonálních kryoglobulinů, tj. 1,07 %. Kryoprecipitace je tedy prokazována v klinické biochemii vzácně, ale ne raritně. V práci se diskutuje také o metodických postupech používaných při průkazu kryoglobulinů a autoři poukazují na potřebu jejich standardizace., The publication contains basic information about cryoglobulins. The results of determination of the cryoglobulins in the group of 3392 monoclonal immunoglobulins are present. Authors proved 37 monoclonal cryoglobulins (1.07%). The publication also discusses the methods for detection and analysis of cryoglobulins., Tichý M., Maisnar V., Hrnčíř Z., Vávrová J., Palička V., and Lit.: 5
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
4. Možná interference paraproteinů při stanovení glykovaného hemoglobinu u dvou pacientů
- Creator:
- Friedecký, Bedřich, Šolcová, L., Špirková, Jana, Maisnar, Vladimír, Kudlej, J., Vávrová, Jaroslava, and Tichý, Miloš
- Type:
- model:article, article, Text, kazuistiky, and TEXT
- Subject:
- lidé, staří, mužské pohlaví, ženské pohlaví, monoklonální gamapatie nejistého významu--krev, imunoglobuliny - kappa-řetězce--krev, imunoglobuliny - lambda-řetězce--krev, diabetes mellitus 2. typu--krev, hemoglobin A glykosylovaný--analýza, krevní glukosa--analýza, chromatografie vysokotlaká kapalinová--přístrojové vybavení, reprodukovatelnost výsledků, financování organizované, and sérum--chemie
- Language:
- Czech and English
- Description:
- Popisujeme dva případy léčených kompenzovaných diabetiků s prokázanou přítomností paraproteinů v krevním séru. U obou z nich byly nalezeny výsledky HbA1c, neodpovídající jejich klinickému stavu a hodnotám plazmatické glukózy. Výsledky HbA1c byly porovnány s použitím dvou metod (obou na principu HPLC) měřením ve dvou různých laboratořích. U prvního pacienta s přítomností IgA kappa paraproteinu (48 g/l) poskytlo měření na přístroji DC-5 výsledky odpovídající dekompenzovanému diabetikovi a pacientovi bez diabetu v případě přístroje Variant II Turbo. U druhého pacienta s přítomností IgM lambda paraproteinu (27 g/l) byly oběma metodami opakovaně zjištěny neadekvátně nízké hodnoty HbA1c. Protože byla popsána řada interferencí paraproteinů při stanovení několika analytů krevního séra, považujeme za vhodné na tyto případy upozornit a pokračovat v podrobnějším studiu v budoucnosti na větším souboru diabetiků s prokázanou přítomností některého paraproteinu., We describe two causes of treated diabetic patients with paraproteinemia. In both cases the results of HbA1c show strong discrepancies with clinical statement and with plasma glucose concentrations. HbA1c results were controlled by repeated measurements by other method in other laboratory. Different results were obtained. In case of fi rst patient with IgA kappa paraprotein (48 g/l) show results of HbA1c obtained by method DC-5 picture of decompensated diabetes, results of Variant II Turbo picture of non-diabetes person, while glucose and clinical state indicated well compensation of diabetes. In case of the second patient with IgM lambda paraprotein (27 g/l) there were very low and improbable results in both HbA1c methods, while clinical statement and plasma glucose were in entire concordance with picture of well compensated diabetes. Interferences of paraproteins are very often observed in some biochemical analyses, but interference of paraprotein in HbA1c measurement is unusual. We wish to alert on this possibility, because in old diabetic patients increases number of persons with paraprotein., Friedecký B., Tichý M., Šolcová L., Špirková J., Maisnar V., Kudlej J., Vávrová J., and Lit.: 9
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
5. Poskytují producenti laboratorních diagnostik dostatek dat o referenčních intervalech?
- Creator:
- Friedecký, Bedřich, Kratochvíla, Josef, and Vávrová, Jaroslava
- Type:
- model:article, article, Text, and TEXT
- Subject:
- reagenční soupravy diagnostické, referenční hodnoty, kalibrace, and mezinárodní soustava jednotek
- Language:
- Czech and English
- Description:
- Smyslem sdělení je vyhodnotit úroveň dat o referenčních intervalech u dvou vybraných skupin analytů srovnáním s kritérii plynoucími z teorie referenčních intervalů. U vybraných základních analytů krevního séra (glukóza, cholesterol, kreatinin, ALT, celkový protein, albumin) byla konstatována obecně přílišná šíře intervalů dolních a horních referenčních limitů neslučitelná s existencí návaznosti u těchto analytů, nedostatečné respektování pohlavního dimorfi smu (ALT a kreatinin), nerespektování evropských diagnostických doporučení (cholesterol) a přenos dat, pocházejících z výběru nevhodné referenční populace do českých podmínek (ALT). U devíti imunochemických stanovení byla posouzena úroveň specifi kace referenčních populací. Ve většině případů nebylo poskytnuto dostatek demografi ckých a geografi ckých údajů. Pracovní návody producentů běžně pracují s různými jednotkami měření, a poskytují tak možnost vydávání zcela různých numerických výsledků totožných analýz. To zvyšuje riziko chyb při diagnóze a léčbě pacientů., We assessed level of information on reference intervals provided by manufacturers for clinical laboratories. Theory of reference intervals based on IFCC approach served as criterion to this assessment. In case of selected routine analyte of blood serum (cholesterol, glucose, creatinine, ALT, total protein, albumin) different manufacturers appear to provide too broad interval of lower and upper reference limits for these analytes as compared with with established metrological traceability of results. Partitioning according to sex is not introduced in three manufacturers for creatinine and two for ALT. The data provided for ALT correspond to Scandinavian reference population but not to Czech healthy persons. Values derived from American diagnostic recommendations were used for cholesterol instead of European recommended values. Data on reference population were assessed for nine immunochemical analytes, produced by two manufacturers. Especially the lack of demographic and geographic information was found. Working protocols of manufacturers use in most cases more different measurement units and even provided more numerical values for the same analyses. This fact strongly increases the risk in the health care. Providing the reference intervals including information on reference population is obligation of manufacturers given by Directive IVD 98/79. Despite this fact many manufacturers require establishment of their own reference intervals in users’ laboratories., Friedecký Bedřich, Vávrová J., Kratochvíla J., and Lit.: 17
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
6. Přehled metod na stanovení volných lehkých řetězců
- Creator:
- Tichý, Miloš, Vávrová, Jaroslava, Friedecký, Bedřich, and Maisnar, Vladimír
- Type:
- model:article, article, Text, and TEXT
- Subject:
- imunoglobuliny - lehké řetězce--analýza--krev, imunodifuze--metody, imunoglobuliny - kappa-řetězce--krev, imunoglobuliny - lambda-řetězce--krev, and elektroforéza proteinů krevního séra
- Language:
- Czech and English
- Description:
- Práce podává základní informace o lehkých řetězcích imunoglobulinů. V přehledu uvádí vývoj metod používaných v klinické biochemii na jejich stanovení. Upozorňuje na četné limity a problémy stanovení volných lehkých řetězců a na jejich možné klinické využití., The publication contains basic information about free light chains of immunoglobulins. In a short review it shows evaluation methods used in clinical biochemistry for the determination of free light chains of immunoglobulins. Authors summarize methodical limitation of determination of free light chains and discuss their clinical utilization., Tichý Miloš, Vávrová J., Friedecký B., Maisnar V., and Lit.: 22
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
7. Stanovení koncentrace celkové bílkoviny v moči s pozitivní Bence Jonesovou bílkovinou
- Creator:
- Tichý, Miloš, Maisnar, Vladimír, Stulík, Jiří, Vávrová, Jaroslava, Friedecký, Bedřich, Palička, Vladimír, Špirková, Jana, Žaloudková, Lenka, Hernychová, Lenka, Spáčilová, Jana, Büchler, Tomáš, and Hájek, Roman
- Type:
- model:article, article, Text, and TEXT
- Subject:
- proteinurie--diagnóza, klinické laboratorní techniky--normy, Benceův-Jonesův protein--analýza, řízení kvality, imunoglobuliny - lehké řetězce--moč, lidé, and financování organizované
- Language:
- Czech and English
- Description:
- Cíl: V rámci externí kontroly kvality SEKK, Gamapatie GP2/08 obdrželo 64 českých klinických laboratoří a 15 slovenských laboratoří vzorek moči od nemocné mnohočetným myelomem s Bence Jonesovou bílkovinou typu lambda. Metody: Laboratoře provedly typizaci paraproteinu v moči imunofi xací a stanovení celkové koncentrace bílkoviny v moči různými metodami, především turbidimetrií, metodou s pyrogallovou červení a s biuretovým činidlem. Výsledky: Získané výsledky byly významně rozdílné. Metodou vysokorozlišovací dvourozměrné elektroforézy s následným westernblottingem byly ve zkoumané moči prokázány především fragmenty lehkých řetězců lambda o molekulové hmotnosti 12 000 Da. Závěr: Stanovení koncentrace celkové bílkoviny v moči je z různých důvodů poměrně obtížné. Tato skutečnost je ještě zvýrazněna při přítomnosti fragmentů Bence Jonesovy bílkoviny v moči, jak prokázala i tato práce., Background: The optimal method for the measurement of urinary monoclonal free light chain (FLC) concentration has not been established. We have carried out an external quality control assessment with the participation of 79 clinical biochemistry laboratories from the Czech Republic and Slovakia. Methods: The laboratories received a reference urine sample obtained from a patient with multiple myeloma and lambda FLC proteinuria and were asked to type the paraprotein using immunofi xation and to measure total urinary protein using their established method, most commonly turbidimetry, pyrogallol red assay, and biuret assay. Results: There was a very wide inter-laboratory variability in the protein concentration readouts with up to three-fold difference in some cases. High-resolution two-dimensional electrophoresis showed that a high proportion of the urinary paraprotein was composed of lambda light chain fragments with molecular weight of 12 kDa. Conclusions: Our results highlight the challenges of reliable and reproducible measurement of urinary protein concentration in the presence of urinary FLCs., M. Tichý, V. Maisnar, J. Stulík, J. Vávrová, B. Friedecký, V. Palička, J. Špirková, L. Žaloudková, L. Hernychová, J. Spáčilová, T. Buchler, R. Hájek, and Lit.: 14
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
8. Stanovení volných lehkých řetězců imunoturbidimetrií a metodou ELISA
- Creator:
- Vávrová, Jaroslava, Friedecký, Bedřich, Tichý, Miloš, Holečková, Magdalena, Maisnar, Vladimír, and Hájek, Roman
- Type:
- model:article, article, Text, and TEXT
- Subject:
- imunoglobuliny - lehké řetězce--krev, ELISA, nefelometrie a turbidimetrie--metody, imunochemie--metody, reagenční soupravy diagnostické, and The Binding Site
- Language:
- Czech and English
- Description:
- Cíl: Ověření základních vlastností analýzy volných lehkých řetězců v séru. Metody: Imunoturbidimetrické stanovení s použitím diagnostické soupravy FreeLite firmy The Binding Site, adaptované na analyzátor Modular Roche. Metoda ELISA, použitá v soupravě firmy BioVendor. Výsledky: Hodnoty stanovené u souboru dárců krve mužů a žen. Index kappa/lambda imunoturbidimetrií 0,53–1,92; metodou ELISA 0,24–1,17. Přesnost měření kappa imunoturbidimetrií 5,6–6,9 %, metodou ELISA 6,6–11,0 %, lambda imunoturbidimetricky 6,1 až 9,2 %, metodou ELISA 7,3–8,6 %. Studovali jsme vliv ředění vzorků na výsledky analýz a potvrdili jsme potřebnost ověřování stupně ředění u každého patologicky změněného vzorku. Regresní analýzou byla určena rovnice y = -9,84 + 1,53 x a korelační koeficient r = 0,73. U imunoturbidimetrie bylo ve sledované populaci nalezeno 58,9 % výsledků hodnocených jako patologických, metodou ELISA 45,5 %. U 4,5 % patologických výsledků byla nalezena neshoda mezi oběma metodami. U výsledků uvnitř referenčního intervalu byly nalezeny neshody u 17,8 % pozorování. Diskuse: Hlavními problémy úspěšného použití stanovení volných lehkých řetězců jsou validita referenčních intervalů, ředění vzorků individuálních pacientů, diference v diagnostické klasifikaci při použití různých metod. Závěr: Stanovení volných lehkých řetězců v séru nelze prozatím považovat za úplně rutinní záležitost, vyžaduje pečlivou přípravu vzorků a analýzu výsledků podmíněnou nadstandardní úrovní odbornosti laboratorního personálu., Objective: Verification of measurement procedures for serum free light chains analysis. Methods: Immunoturbidimetric measurement with using the FreeLite kit (The Binding Site), adapted on the Modular P (Roche). ELISA method performed by kit BioVendor. Results: The ratio kappa/lambda of blood donors values in men and women was from 0.53 to 1.92 by use FreeLite kit and from 0.24 to 1.17 by ELISA method. We obtained measurement precision as follows: kappa (FreeLite) 5.6–6.9%, 6.6–11.0% (ELISA), lambda 6.1–9.2% by FreeLite and 7.3–8.6% by ELISA kit. We assessed the influence of sample dilution on the results. It is necessary to verify dilution in each pathologically changed sample. Regression analysis is expressed by equation y = -9.84 + 1.53 x and Pearson regression coefficient is r = 0.73. We found 58.9% results obtained with immunoturbidimetry, but only 45.5% of results obtained by ELISA method out off reference limit. Four and a half % of pathologic results showed disagreement frequency in paired results while in results inside reference interval there was a disagreement frequency even 17.8%. Conclusion: It is unsuitable to consider the measurement of free light chains in serum as a routine event. This determination requires careful work and high professional level of laboratory personal., Vávrová Jaroslava, Friedecký B., Tichý M., Holečková M., Maisnar V., Hájek R., and Lit.: 9
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public