Aim: The principal aim was to establish reference paediatric data for the serum homocysteine levels in Czech children and adolescents. Methods and Results: 144 children either healthy or not sufferig from acute or chronic inflammation, autoimmune disorders including rheumatic diseases, inflammatory musculoskeletal disorders, inflammatory bowel disease, diabetes mellitus, hypercholesterolemia, epilepsy, chronic renal failure, aged 0–19.9 years (0–6.9 years, n = 40; 7–10.9 y, n = 28; 11–15.9 y, n = 45; 16–19.9 y, n = 31) had their blood samples collected and the serum homocysteine level (S-homocysteine) was evaluated by chemiluminescence. A significant age dependence of the S-homocysteine levels was observed (R = 0.35, p < 0.01); with highest values of upper reference range in the 11–15.9 and 16–19.9 years’ group, respectively. Conclusion: The establishment of S-homocysteine reference Czech pediatric values is a potentially useful tool for proper evaluation of elevated homocysteine levels and corresponding risks in childhood., Vladimír Němec, Eva Bočkayová, Štěpán Kutílek, and Literatura 30
Kolorektální karcinom v těhotenství je vzácné, ale velmi závažné onemocnění. Autoři prezentují kazuistiku pacientky s časným karcinomem sigmoidea v těhotenství a problematiku diskutují ve světle současných literárních poznatků. Klíčová slova: kolorektální karcinom – těhotenství – diagnostika – terapie – prognóza, Colorectal cancer in pregnancy is a rare but life-threatening disease. The authors present a case of early-stage sigmoid colon cancer in pregnancy, discussing the issue in the light of the current literature. Key words: colorectal cancer – pregnancy – diagnosis – treatment – prognosis, and P. Kocián, J. Hoch, M. Halaska
Cíl: Cílem této pilotní studie byl celogenomový screening metylace DNA u pacientek s nádory ovarií. Sledování metylace bylo zaměřeno jak do promotorových oblastí vybraných genů, tak do ostrůvků bohatých na CpG. Typ studie: Pilotní studie. Materiál a metody: Do studie bylo zařazeno šest vzorků získaných od pacientek s nově diagnostikovaným ovariálním karci - nomem a šest vzorků nenádorových ovárií. Vzorky byly analyzovány pomocí zákazníkem navržených metylačních mikročipů založených na metylované-DNA imunoprecipitaci. Výsledky: Pomocí mikročipů navržených ve spolupráci se specialisty firmy HPST se nám podařilo poukázat u nádorové tká - ně na tendenci k celkové hypometylaci DNA. Dále se nám podařilo získat soubor hypermetylovaných genů ke konfirmačním analýzám. Závěr: Vzhledem k tomu, že změny v metylaci DNA jsou jedním z prvních projevů v průběhu karcinogeneze, mohly by být nalezené změny, v případě jejich průkazu v plazmě pacientek, v budoucnu využity jako screeningové markery u rizikové populace. Monitorování metylace DNA by mohlo přispět ke zlepšení péče o nemocné s ovariálním karcinomem, včetně možné finanční úspory díky včasné diagnóze a případné predikci odpovědi na léčbu, Objective: The aim of this pilot study was whole-genome screening of DNA methylation in ovarian cancer patients. Monito - ring of DNA methylation was focused on promoter regions and also on CpG islands. Design: Pilot study Material and methods: Our study included 6 samples obtained from patients with newly diagnosed ovarian cancer and 6 nonmalignant control samples of ovaries. All samples were analysed using a custom designed methylation microarrays based on the methylated DNA immunoprecipitation. Results: Using microarrays designed in collaboration with specialists of the HPST company we found in the tumor tissue tendency to overall DNA hypomethylation. Furthermore we managed to get a set of hypermethylated genes for confirmation analyses. Conclusion: DNA methylation changes are considered to be a one of the first changes during carcinogenesis. Due to this fact could be newly identified changes, in case of detection in plasma of ovarian cancer patient, used as screening markers in risk population. Monitoring of DNA methylation could contribute to improve the care of ovarian cancer patients, including possible financial saving due to early diagnosis and possible prediction of response to treatment., Chmelařová M., Ruszová E., Laco J., Dvořáková E., Smetana J., Hrochová K., Palička V., and Literatura
Karcinoid patří mezi neuroendokrinní tumory, které mohou produkovat endokrinně aktivní látky. Představuje 1–2 % plicních tumorů. Dle svých histopatologických charakteristik se dělí na typický a atypický karcinoid, od čehož odvisí i prognóza (13, 24). Typický karcinoid (TC) má příznivou prognózu, je často zjištěn náhodně, pětileté přežití je přes 90 %. Atypický karcinoid (AC) se vyznačuje agresivnějším chováním, časnějším metastazováním i nižším dlouhodobým pětiletým přežitím (40–60 %) (5, 13). Sledovali jsme soubor 52 pacientů s histologicky potvrzenou diagnózou karcinoidu, kteří se na naší klinice léčili v období 2002–2013. Typický karcinoid byl diagnostikován u 35 pacientů (67 %), u 17 pacientů (33 %) se jednalo o karcinoid atypický. Sledování potvrdilo v literatuře uváděné četnosti výskytu a prognózu pacientů, analyzuje též možnosti a efektivitu endobronchiální léčby a výsledky léčby obou typů nádoru. Zajímavým zjištěním je vysoká incidence duplicitních (i triplicitních) malignit u pacientů s atypickým karcinoidem (25 % nemocných)., Carcinoid is a neuroendocrine tumour that can produce endocrine active substances. It represents 1-2 % of pulmonary tumours. Based on histopathological characteristics, it is divided into typical and atypical carcinoid, which also affects the prognosis. {11,18} Typical carcinoid (TC) has a favourable prognosis, is often found incidentally, and the five-year survival rate is over 90 %. Atypical carcinoid (AC) exhibits a more aggressive behaviour, more frequent metastasizing, and a lower five-year survival rate (40-60 %). {5,11} We followed up a group of 52 patients with a histologically confirmed diagnosis of carcinoid who were treated at our clinic in the years 2002 to 2013. Typical carcinoid was diagnosed in 35 patients (67 %) and 17 patients (33 %) had atypical carcinoid. The follow-up confirmed the incidence rates and prognosis of patients reported in the literature, while analyzing the options and efficacy of endobronchial treatment and the results of treatments for both types of tumours. Interestingly, a high incidence of double (as well as triple) malignancies was found in patients with atypical carcinoid (25 % of patients)., Ondřej Fischer, Juraj Kultan, Jana Kulísková, Ivona Grygárková, Vítězslav Kolek, Tomáš Tichý, and Literatura
Jedná se o prospektivní pilotní studii zaměřenou na vyšetřování vývoje tvaru a statiky páteře u dětí pomocí neinvazivní somatografické metody systémem DTP při vyšetřování kvality posturální funkce. Sledovaný soubor tvořilo 47 dětí v mladším školním věku a byly vyšetřeny dvakrát (v 1. a v 5. třídě ZŠ). Během sledování došlo ke statisticky významnému prohloubení krční lordózy v celém souboru, tj. u dívek i chlapců, k prohloubení bederní lordózy došlo pouze u chlapců. Celkově ke zlepšení držení těla došlo u 15 %, k celkovému zhoršení držení těla u 53 % a beze změny postury zůstala 4 % dětí vyšetřovaného souboru. Z našich šetření vyplývá 1) nestabilita posturální funkce v tomto sledovaném období, která naznačuje možnost efektivity preventivních opatření v podobě optimální zátěže; 2) možnost upřesnění stávajícího somatoskopického vyšetřování použitím neinvazivního přístroje., The aim of the prospective pilot study was the investigation of the development of postural function (spinal shape and statical properties of the spine) in children by the non-invasive DTP system. The sample consisted of 47 children of primary school age who were examined twice – in the 1st and 5th grade of elementary school. Exacerbation of cervical lordosis was statistically documented during follow-ups in both genders, while worsening of lumbar lordosis was proven only in boys. Overall, posture was improved in 15%, deteriorated in 53% and remained unchanged in 4% of examined children. Our study reveals: i) postural instability in this reporting period, which suggests the possible effectiveness of preventive measures in the form of optimal load; ii) the possibility of clarifying somatoscopic investigation using non-invasive apparatus., Jana Langmajerová, Marta Bursová, Jana Dvořáková, Dana Müllerová, and Literatura 13
Cíl: Vytvoření kvalitního digitálního obrazu systémem ClarityIQ na angiografickém přístroji AlluraClarity Xper FD 20/20 (Philips Medical System, Best, Holandsko) je spojeno s nižší radiační zátěží pacienta než u předchozí generace přístrojů. Cílem práce bylo srovnání efektivních dávek ionizujícího záření na dvou angiografických přístrojích Allura Xper FD 20 (Philips Medical System, Best, Holandsko) a Philips Allura Clarity Xper FD 20/20 (Philips Medical System, Best, Holandsko). Metodika: V retrospektivní studii jsme analyzovali konsekutivně vybraných 100 angio-intervenčních vyšetření provedených u 100 nemocných v časovém období od 1. 7. 2012 do 1. 7. 2013. Na angiografickém kompletu Philips Allura Clarity Xper FD 20/20 (Philips Medical System, Best, Holandsko) s technologii ClarityIQ byla konsekutivně vybrána vyšetření 50 nemocných (34 mužů, 16 žen průměrného věku 64 let, průměrné hmotnosti 79 kg a průměrné výšce 170 cm). Na přístroji Allura Xper FD 20 (Philips Medical System, Best, Holandsko), který nepracuje se systémem ClarityIQ, bylo konsekutivně vybráno 50 pacientů (30 mužů, 20 žen, průměrného věku 64 let, průměrné hmotnosti 78 kg a průměrné výšce 170 cm). Dané skupiny byly rozděleny podle druhu intervenčního výkonu na podskupiny čítající 10 provedených intervenčních vyšetření na každém z přístrojů: vytvoření transjugulárních intrahepatálních portosystémových spojek (TIPS), zavedení břišních stentgraftů u aneuryzmatu břišní aorty, provedené neurointervenční ošetření u pacientů po prodělaném subarachnoideálním krvácení z aneuryzmatu na mozkové cévě (SAK), provedené neurointervenční ošetření u pacientů s prodělanou cévní mozkovou příhodou (CMP), provedené neurointervenční ošetření zavedením stentu u pacientů s karotickou stenózou (CAS). U vytvořených podskupin jsme výpočtem stanovili hodnoty efektivních dávek. Statistická významnost snížení efektivních dávek pacientů vyšetřených na přístroji vybaveném systémem ClarityIQ byla prokázána testem ve statistickém programu NCSS 2007. Výsledky: Významné snížení radiační zátěže použitím systému ClarityIQ bylo prokázáno výrazným poklesem efektivních dávek. Snížení efektivní dávky se pohybovalo od 50 % do 70 % a bylo statisticky významné. Závěr: Systém ClarityIQ významně snižuje radiační zátěž pacienta spojenou s výkony v oblasti intervenční radiologie, a proto by měla být přístrojům s podobnými systémy dána přednost., Aim: Creation of a high-quality digital image system ClarityIQ on angiography equipment AlluraClarity Xper FD 20/20 (Philips Medical System, Best, The Netherlands) is associated with lower patient radiation burden than the previous generation of equipments. The aim of the study was to compare the effective doses of ionizing radiation on two angiographic intervention equipments Allura Xper FD 20 (Philips Medical System, Best, The Netherlands) and Philips Allura Xper FD Clarity 20/20 (Philips Medical System, Best, The Netherlands). Methods: In this retrospective study we analyzed 100 interventional examinations consecutively performed in 100 patients from 1st July 2012, until 1st July 2013. Fifty patients (34 males, 16 females, mean age 64 years, average weight 79 kg and average height 170 cm) were examined using the angiography set Philips AlluraClarity FD 20/20 employing the ClarityIQ technology. Fifty patients (30 males, 20 females, mean age 64 years, average weight 78 kg and average height 170 cm) were examined using the Allura Xper FD 20 set that does not work with the ClaritylQ system. The groups were divided according to the type of intervention on the performance of subgroups comprising 10 interventional procedures on each of the machine: the creation of transjugular intrahepatic portosystemic shunts (TIPS), the implantation of abdominal stentgrafts for abdominal aortic aneurysm, neurointerventional procedures in patients after subarachnoideal hemorrhage from a cerebral aneurysm (SAH), neurointerventional treatment of the patients with ischemic stroke, patients with carotid artery stenting (CAS). The generated subgroups are determined by calculating the values of effective doses. The statistical significance of the reduction in effective doses of patients examined on the device that is equipped with ClaritylQ was demonstrated by tests of statistical program NCSS 2007. Results: Significant reduction of radiation burden to patients has been shown by significant decrease of effective doses in the ClarityIQ system. The effective dose decrease ranged from 50% to 70% and was proved to be statistically significant. Conclusion: The ClarityIQ significantly reduces radiation dose to the patient associated with the performance of interventional radiology procedures, and therefore equipments with similar systems should be preferred., Michal Rek, Jakub Grepl, Antonín Krajina, Eva Čermáková, Radovan Malý, Vendelín Chovanec, Ondřej Renc, Jan Raupach, and Literatura
Úvod: Kardiochirurgické výkony jsou zatíženy signifikantním rizikem vzniku ischemické cévní mozkové příhody (CMP), které se dle jednotlivých studií pohybuje mezi 1,3 a 3,6 %. Asymptomatické ischemické infarkty lze detekovat po kardiochirurgické operaci dokonce až u 32 % pacientů. Cílem studie je prokázat efekt sonolýzy (kontinuálního transkraniálního dopplerovského (TCD) monitoringu a. cerebri media (ACM)) u pacientů podstupujících kardiochirurgický výkon na snížení rizika vzniku nových ischemických lézí detekovaných pomocí magnetické rezonance (MR). Soubor a metodika: Do studie jsou zařazováni pacienti indikovaní k izolovanému aortokoronárnímu bypassu nebo k izolovanému výkonu na jedné srdeční chlopni. Pacienti jsou randomizováni do skupiny se sonolýzou (monitorování pomocí TCD) a kontrolní skupiny bez sonolýzy. U všech pacientů byla provedena MR mozku před výkonem a 24 hod po něm a byla hodnocena četnost výskytu, lokalizace a velikost nových ischemických změn po výkonu. Výsledky: Během 16 měsíců bylo zařazeno 78 pacientů (48 mužů, průměrný věk 63,7 ? 15,8 let), 35 pacientů bylo randomizováno do skupiny se sonolýzou, 43 pacientů do kontrolní skupiny. Ve skupině sonolýzy byly detekovány nové ischemické změny u osmi pacientů (23 %) – u pěti (14 %) v povodí pravé (stimulované) ACM, ale jen u dvou (6 %) větší než 0,5 cm3. V kontrolní skupině byly detekovány nové ischemické změny u 10 pacientů (23 %) – u osmi (19 %) v povodí pravé ACM, u pěti (12 %) větší než 0,5 cm3 (p > 0,05 ve všech případech). Závěr: Pilotní data studie prokázala trend k redukci počtu i objemu ischemických lézí mozku u pacientů se sonolýzou v průběhu kardiochirurgické operace., Background: Heart surgery is burdened with a significant risk of ischemic stroke. Asymptomatic cerebral infarctions can be detected in as many as 32% of patients after heart surgery. The aim of this study is to prove the efficacy of sonolysis (continual transcranial Doppler (TCD) monitoring) during open-heart surgery to decrease the risk of new brain infarctions detected by magnetic resonance imaging (MRI). Material and methods: Patients indicated to isolated coronary artery bypass or isolated one heart valve surgery were included in the study. Patients were randomized to a sonolysis group (TCD monitoring), and to a control group without sonolysis. All patients underwent brain MRI before and 24 hours after the surgery and the presence of new ischemic lesions was evaluated. Results: During 16 months, 78 patients (48 males, mean age 63.7 ? 15.8 years) were enrolled to the study. Thirty five patients were randomized to the sonolysis group and 43 to the control group. In the sonolysis group, new brain infarctions were found in eight (23%) patients – in the right (TCD-monitored) MCA territory in five patients (14%) but > 0.5 cm3 in two (6%) patients only. In the control group, new infarctions were found in 10 patients (23%) – in the right (TCD-monitored) MCA in eight (19%) patients and > 0.5 cm3 in five (12 %) (p > 0.05 in all cases). Conclusion: Pilot study results showed a trend towards reduction in a number and volume of new brain ischemic lesions in patients treated with sonolysis during heart surgery. Key words: ultrasound – sonolysis – brain ischemia – coronary artery bypass graft – heart valve – magnetic resonance imaging – brain The authors declare they have no potential conflicts of interest concerning drugs, products, or services used in the study. The Editorial Board declares that the manuscript met the ICMJE “uniform requirements” for biomedical papers., and E. Hurtíková, M. Roubec, M. Kuliha, A. Goldírová, J. Havelka, R. Brát, M. Bortlíček, R. Herzig, D. Školoudík
Úvod: Cílem článku je představení analogu somatostatinu EDDA/HYNIC-TOC značeného 99mTechneciem (Tektrotyd), který je v České republice dostupný od roku 2011. Radiofarmakum se používá k scintigrafické lokalizaci nádorů se somatostatinovými receptory. Materiál a metoda: Na Klinice nukleární medicíny a endokrinologie v Motole jsme od září 2011 dosud vyšetřili 18 pacientů. Jednalo se o 3 pacienty s medulárním karcinomem štítné žlázy (MTC), 12 pacientů s neuroendokrinním tumorem (NET) nebo karcinoidem, 2 pacienty s podezřením na přítomnost karcinoidu a 1 pacient byl indikován pro endokrinní orbitopatii. Protokol vyšetření zahrnuje celotělové snímání a tomografickou akvizici za 4 hodiny po aplikaci 700 MBq Tektrotydu. Za 1-2 hodiny po aplikaci doplňujeme SPECT břicha. Výsledky: Patologický nález jsme pozorovali u 6 pacientů. U všech pacientů byl nález ve shodě s jinými vyšetřovacími metodami. Zobrazení nadledvin jsme pozorovali u 10 vyšetřených. Nález nebyl interpretován jako patologie, vysvětlujeme si ho dosahovaným vyšším rozlišením a zlepšenou kvalitou obrazů. U 12 pacientů bylo vyšetření negativní. Závěr: 99mTc EDDA/HYNIC-TOC (Tektrotyd) může být alternativou k užití 111In-DTPA-D-Phe1-octreotidu (Octreoscan) při vyšetřování nemocných s tumory exprimujícími somatostatinové receptory. Výhodou je větší dostupnost radiofarmaka, nižší radiační zátěž a vyšší kvalita zobrazení. K vyloučení falešně pozitivních nálezů v dutině břišní vzhledem k hepatobiliární exkreci je užitečné provádět dvě tomografická vyšetření břicha, přičemž první by mělo být provedeno mezi 1. a 2. hodinou po aplikaci., Introduction: The aim of this article is to introduce the somatostatin analog EDDA/HYNIC-TOC labeled with 99mTechnetium available in Czech Republic since 2011. This radiopharmaceutical has been used for scintigraphic localisation of tumors bearing somatostatin receptors. Material and methods: We evaluated 18 patients in our department from September 2011. There were 3 pts with medullary thyroid cancer, 12 pts with neuroendocrine tumor (NET) or carcinoid, 2 pts with suspected carcinoid and 1 pt due to endocrine orbitopathy. Imaging consists of whole-body scan and SPECT/CT performed 4 hours post injection of 700 MBq of Tektrotyd. We add an abdominal SPECT 1 to 2 hours post injection. Results: Positive findings were detected in 6 pts. It was in agreement to other diagnostic methods. We detected accumulation in the suprarenal glands in 10 pts. This was not interpreted as a pathology, we believe this detection is thanks to a better resolution and an improved image quality. 12 pts were negative. Conclusion: 99mTc EDDA/HYNIC-TOC (Tektrotyd) could be a good alternative to 111In-DTPA-D-Phe1-octreotide (Octreoscan) in evaluating patients with tumors bearing somatostatin receptors. Better availability, lower radiation and improved image quality are the advantage. Early tomographic imaging of abdomen should be done to avoid false positive findings due to nonspecific tracer accumulation., Kateřina Táborská, and Literatura 9
Cílem této práce je prezentovat první u nás provedenou angioplastiku hemodialyzačního zkratu pod ultrasonografickou kontrolou. Jednalo se o pacientku v pravidelném hemodialyzačním programu, která byla indikována k PTA (perkutánní transluminální angioplastika) odvodné žíly svého nativního dialyzačního zkratu. Pro prudkou anafylaktoidní reakci na kontrastní látku, však bylo její opětovné podání kontraindikované, proto jsme se rozhodli pro ultrasonograficky navigovanou PTA ve druhé době. Výkon byl úspěšný což prokázalo sonografické hodnocení i měření provedená na dialýze. Naše zkušenost ukázala, že zobrazení instrumentaria pod sonografem je dobré, a provádění sonograficky navigované PTA je tedy možné., In this article we would like to present the first angioplasty of haemodialysis fistula under ultrasonography guidance which was performed in our department. PTA (percutaneous transluminal angioplasty) of a draining vein of a native fistula was indicated in a patient who was included in hemodialysis program. As contrast media administration was contraindicated for previous severe adverse effect, we decided to perform PTA under ultrasonography guidance. The procedure was successful; the effect was proven both by ultrasonography and measurement in dialysis. Our experience shows that ultrasonography provides good visualization of instruments and therefore ultrasonography-guided PTA is possible., Jan Kaván, Jan Malík, Eva Chytilová, Lubomíra Forejtová, Jiří Křivánek, Vratislava Kovářová, and Literatura