When parasites invade paired structures of their host non-randomly, the resulting asymmetry may have both pathological and ecological significance. To facilitate the detection and visualisation of asymmetric infections we have developed a free software tool, Analysis of Symmetry of Parasitic Infections (ASPI). This tool has been implemented as an R package (https://cran.r-project.org/package=aspi) and a web application (https://wayland.shinyapps.io/aspi). ASPI can detect both consistent bias towards one side, and inconsistent bias in which the left side is favoured in some hosts and the right in others. Application of ASPI is demonstrated using previously unpublished data on the distribution of metacercariae of species of Diplostomum von Nordmann, 1832 in the eyes of ruffe Gymnocephalus cernua (Linnaeus). Invasion of the lenses appeared to be random, with the proportion of metacercariae in the left and right lenses showing the pattern expected by chance. However, analysis of counts of metacercariae from the humors, choroid and retina revealed asymmetry between eyes in 38% of host fish., Matthew T. Wayland, James C. Chubb., and Obsahuje bibliografii
An electronic nose system for herbs clcissification is designed and tested. The system uses the Figaro TGS800 series sensors with an integrated heating element. The testing of the system was carried out using diíferent types of herbs where it was proved to be successful in classifying them into diíferent classes [10, 11]. Database-based software was designed to interface the built hardware and to process the electronic nose signals before being classified.
Cíl. Práce je zaměřena na možnosti provedení CT angiografie břišní aorty a dolních končetin na nové generaci dvouzdrojového CT přístroje využívající skenování s vysokým pitch faktorem a ohledem na redukci radiační zátěže a množství podávané kontrastní látky. Metoda. V rámci prospektivní studie bylo vyšetřeno 29 osob s klinickými známkami či již známým postižením tepen dolních končetin. Vyšetření byla provedena na přístroji Somatom Definition FLASH (Siemens, Německo), použita kolimace 128 x 0,6 mm, rychlá rotace rentgenky (0,28 s/otáčku) a vyšším fázovým posunem (pitch faktor 1,55). Kontrastní látka v množství 60-70 ml byla aplikována rychlostí 5 ml/s, načasování akvizice bylo provedeno na základě monitorace testovacího bolusu (10 ml) v popliteálních tepnách. Hodnocení kvality zobrazení bylo provedeno na základě vizuálního posouzení a stanovení denzity v jednotlivých částech tepenného systému. Výsledky. Ve všech případech bylo dosaženo vysoké kvality zobrazení aorty, pánevních, femorálních i popliteálních tepen na základě vizuálního hodnocení i stanovení denzity (aorta - 456,3 HU, třísla - 507,3 HU, podkolenní - 554,3). V případě distální části bérců a nohy došlo u tří osob k suboptimální náplni vlivem rychlejší akvizice vůči postupu bolusu kontrastní látky. Pouze v jednom případě byla distální oblast bérců nehodnotitelná. Průměrná úroveň denzity v úrovni kotníků byla 367,7 HU. Průměrná radiační dávka byla nízká -CTDIvol 2,40, efektivní dávka 1,79 mSv. Závěr. První výsledky naší prospektivní studie prokázaly možnost provedení CT angiografie dolních končetiny pomocí "high-pitch" módu. Přes velmi nízkou hodnotu radiační dávky i aplikovaného množství kontrastní látky bylo dosaženo vysoké diagnostické kvality v oblasti aorty, pánve stehen a proximálních částí bérců. Tento způsob vyšetření je zvlášť vhodný pro osoby s vysokým rizikem kontrastní nefropatie, eventuálně pro mladé osoby v produktivním věku., Aim. Our work was focused on the feasibility of CT angiography of abdominal aorta and lower limbs using new generation of dual-source CT with a high pitch factor, concerning on the reduction of radiation exposure and the amount of administered contrast agent. Methods. In the prospective study were examined 29 patients with clinical signs, or known disability of lower limbs arteries. The examinations were performed on the Somatom Definition Flash (Siemens, Germany) using collimation 128 x 0.6 mm, high tube rotation speed (0.28 s/rotation) and a higher pitch factor of 1.55).Amount of contrast agent (60 to 70 ml) was applied at 5 ml/s, the timing of acquisition was based on results of the test bolus monitoring (10 ml) in the popliteal arteries. Evaluation of image quality was based on visual assessment and determination of density in different parts of the arterial system. Results. In all cases were achieved a high display quality of the aorta, pelvic, femoral and popliteal arteries by visual assessment and also determination of luminal density (aorta - 456.3 HU, groin - 507.3 HU, knee - 554.3). In the region of the distal leg and ankle occurred in 3 people in suboptimal quality due to overrun of bolus. Only in one case, the distal region leg was uninterpretable. The average level density at ankle level was 367.7 HU. The average radiation exposure was low - CTDIvol 2.40,1.79 mSv effective dose. Conclusion. The preliminary results of our prospective study showed the possibility of performing CT angiography of the lower limbs in "high-pitch" mode. Despite the very low radiation dose and the amount of applied contrast agent was achieved a high diagnostic quality of the aorta, pelvic, femoral, popliteal and proximal crural arteries. This test method should be especially recommended for people at high risk of contrast nephropathy and for young people., Jan Baxa, Jiří Ferda, Petr Duras, Jiří Moláček, Petr Havránek, Hynek Mírka, and Literatura 18
Cíl: Sémontův repoziční manévr se v praxi užívá k léčbě pacientů s benigním paroxyzmálním polohovým vertigem zadního polokruhového kanálku. Cílem studie bylo zhodnotit interindividuální a intraindividuální variabilitu při provádění tohoto manévru a definovat parametry, které jeho provedení nejvíce ovlivňují. Metody: Tři zkušení terapeuti provedli manévr oboustranně u 10 zdravých jedinců. Inerciální měřicí jednotka složená z akcelerometru a gyroskopu získávala informace o trajektorii pohybu hlavy v prostoru a její rychlosti. Úhlové změny byly zaznamenány v souřadnicovém referenčním systému. Z odchylek od uvažované roviny polokruhového kanálku byla vyhodnocena data o přesnosti provedení manévru. Výsledky: Parametry ovlivňujícími přesnost manévru jsou výška probanda (p = 0,0252), fáze pohybu (p < 0,0001) a dále terapeut a strana pohybu, přičemž tyto faktory vykazují vliv především ve své interakci. Byl hodnocen vztah fáze pohybu k výšce probandů (p = 0,0130), terapeuta k fázi pohybu (p = 0,0001), terapeuta k výšce probandů (p < 0,0252). Největší zaznamenaný rozsah odchylky od senzorické roviny byl v rozmezí –37,17° až 31° se standardní odchylkou 16,6°. Závěry: Získaná data poukazují na překvapivě vysokou variabilitu při provádění Sémontova manévru ať v porovnání mezi jednotlivými měřeními u jednoho terapeuta nebo v porovnání mezi terapeuty. Analýza vlivu těchto odchylek na úspěšnost terapie benigního polohového paroxyzmálního vertiga a bližší analýza ovlivňujících parametrů by měly být předmětem dalšího výzkumu., Aim: Sémont liberatory manoeuvre is used in the treatment of posterior semicircular canal in patients with benign paroxysmal positional vertigo. The aim of the study was to determine the inter-individual and intra-individual variability in the processing of the manoeuvre and to define the parameters that affect it the most. Methods: Three experienced therapists applied the manoeuvre bilaterally in 10 healthy probands. Inertial measurement unit consisting of the accelerometer and gyroscope recorded the trajectory and speed. Angle changes were placed in the coordinate reference system. Accuracy of the manoeuvre was evaluated based on the deviations from the projected sensory plane. Results: Parameters affecting the accuracy of the manoeuvre included height of a proband (p = 0.0252), phase of the movement (p < 0.0001), therapist and the side of the movement. The effect of these factors is the most pronounced when combined. We assessed interactions of the phase of the movement and the height of the probands (p = 0.0130), the therapist and the phase of movement (p = 0.0001), the therapist and the height of the probands (p < 0.0252). The largest magnitude of deviation from the sensory plane was in the range of –37.17° to 31° with a standard deviation of 16.6°. Conclusions: The data highlight high variability in the implementation of the Sémont liberatory manoeuvre, whether measurements by a single therapist or inter-individually between the therapists are compared. Analysis of the impact of these deviations on therapeutic efficacy in patients with benign paroxysmal positional vertigo and detailed analysis of influencing parameters should be the subject of further research. Key words: benign positional paroxysmal vertigo – variability – Sémont liberatory manoeuvre The authors declare they have no potential conflicts of interest concerning drugs, products, or services used in the study. The Editorial Board declares that the manuscript met the ICMJE “uniform requirements” for biomedical papers., and M. Stehlíková, O. Čakrt, I. Bodlák, Z. Čada, R. Černý, J. Jeřábek
One of the features involved in clustering is the evaluation of distances between individuals. This paper is related with the use of different mixed metrics for clustering messy data. Indeed, in real complex domains it becomes natural to deal with both numerical and symbolic attributes. This can be treated on different approaches. Here, the use of mixed metrics is followed. In the paper, impact of metrics on final classes is studied. The application relates to clustering municipalities of the metropolitan area of Barcelona on the bases of their constructive behavior, the number of buildings of different types being constructed, or the politics orientation of the local government. Importance of the reporting phase is also faced in this work. Both clustering with several distances and the interpretation oriented tools are provided by a software specially designed to support Knowledge Discovery on real complex domains, called KLASS.
Cíl: Zhodnotit efektivitu ambulantního pleopticko‑ortoptického cvičení doplněného o domácí rehabilitaci za pomoci speciálně upraveného softwaru u pacientů s náhle vzniklou okohybnou poruchou a diplopií. Soubor a metodika: Soubor tvořilo 86 dospělých pacientů (33 rehabilitujících – studijní skupina, 53 nerehabilitujících – kontrolní skupina) s náhle vzniklou okohybnou poruchou a diplopií. Příčinou okohybné poruchy byla cévní mozková příhoda, kraniocerebrální poranění nebo vaskulární onemocnění. U všech pacientů bylo provedeno komplexní oční a ortoptické vyšetření s objektivizací okohybné poruchy a diplopie na Lancasterově a Hessově plátně. Sledovací doba byla u obou skupin v intervalu 3–6 měsíců. Výsledky: Průměrné procentuální zlepšení horizontální úchylky šilhání u pacientů s postižením n. VI na jednom oku bylo 96,8 % (p ≤ 0,01) ve studijní skupině, 28,1 % (p ≤ 0,00001) v kontrolní skupině, s postižením n. III a n. IV na jednom oku 73,7 % (p ≤ 0,0008) ve studijní skupině, 36,3 % (p ≤ 0,05) v kontrolní skupině. Průměrné procentuální zlepšení vertikální úchylky šilhání u pacientů s postižením n. III a n. IV ve studijní skupině bylo 43,5 % (p ≤ 0,002), v kontrolní skupině 19,9 % (p ≤ 0,04). Závěr: Studie prokázala vyšší procentuální zlepšení velikosti úchylky šilhání a deficitu hybnosti u dospělých rehabilitujících pacientů ve srovnání se spontánní částečnou úpravou okohybné poruchy u pacientů bez léčby. Domácí rehabilitace za pomoci speciálně upraveného softwaru se jeví jako vhodný doplněk ke klasické léčbě ve formě pleopticko‑ortoptických cvičení, která mají nezastupitelné místo v rehabilitaci okohybných poruch nejrůznější etiologie., Aim: To evaluate efficacy of pleoptic and orthoptic therapy combined with a home rehabilitation program with a support of a specifically‑developed software in patients with ocular motility disorder and diplopia. Methods: Our study involved 86 adult patients with ocular motility disorder and diplopia (33 with rehabilitation – a study group, 53 without any rehabilitation – a control group). The causes of ocular motility disorders included cerebrovascular accident, craniocerebral trauma and vascular disease. A comprehensive ophthalmological and orthoptic examination were performed in all patients. The Hess‑Lancaster screen tests were performed to objectify ocular motility disorder with diplopia. Follow‑up period ranged between 3 and 6 months in both groups. Results: The mean improvement of horizontal deviation in patients with the sixth cranial nerve palsy on one eye was 96.8% in the study group (p ≤ 0.01) and 28.2% in the control group (p ≤ 0.00001), and it was 73.7% in the study group (p ≤ 0.0008), 36.3% in the control group (p ≤ 0.05) in patients with the third and fourth cranial nerve palsy on one eye. The mean improvement of vertical deviation was 43.5% in the study group (p ≤ 0.002), 19.9% in the control group (p ≤ 0.04). Conclusion: This study demonstrates greater improvement of deviation and ocular motility deficit in adult patients who underwent the pleoptic and orthoptic therapy combined with a home rehabilitation program. Key words: paralytic strabismus – diplopia – conservative treatment – rehabilitation The authors declare they have no potential conflicts of interest concerning drugs, products, or services used in the study. The Editorial Board declares that the manuscript met the ICMJE “uniform requirements” for biomedical papers., and L. Pražáková, J. Timkovič, R. Autrata, P. Rezek, P. Novák, L. Bláhová
Pacienti s diabetem 1. typu jsou vystaveni neustálé zátěži vyplývající z nutnosti pečlivého selfmonitoringu glykemie a přesného dávkování inzulinu na základě zjištěných hodnot, obsahu sacharidů v potravě a plánované i neplánované fyzické aktivity. Chyby při dávkování inzulinu se projeví hypoglykemií nebo hyperglykemií, přičemž výskyt hypoglykemií je nejčastějším faktorem limitujícím dosažení optimální kompenzace diabetu. Proto jsou pokroky při vývoji automatických prvků pro dávkování inzulinu v inzulinových pumpách velmi významné i z klinického hlediska. V současnosti dostupné systémy LGS a PLGM umožňují omezit výskyt a dobu strávenou v hypoglykemii a jsou dalším krokem na cestě k uzavřenému okruhu dávkování inzulinu., Patients with type 1 diabetes are exposed to permanent burden consisting of careful glucose self-monitoring and precise insulin dosage based on measured glucose values, carbohydrates content in the food and both planned and non-planned physical activity. Erroneous insulin dosing causes frequent both hypoglycemia and hyperglycemia. Hypoglycemia is, however, the most clinically significant complication limiting the optimal diabetes control. Automatic features for insulin dosage integrated in insulin pumps are thus very important. Low glucose suspend (LGS) and Predictive Low Glucose Management (PLGM) use glucose sensor values to prevent hypoglycemia, shorten the time spent in hypoglycemic range and present further step forward to fully closed-loop system of insulin treatment., and Martin Prázný