An increased risk of myocardial ischemic changes was demonstrated in patients suffering from panic disorder (PD). Using classical ECG methods, this risk cannot be evaluated in most patients. We measured the vectocardiogram (VCG) using Frank orthogonal leads and body surface maps (BSM) including 12-lead ECG. In our study of 11 PD patients (2 men, 9 women), without any seizures and pharmacological treatment and without cardiovascular symptoms, we found marked sinus tachycardia (heart rate 90.1±12.2 min-1) and a shorter R-R interval (678±93.6 ms) than in 27 controls (heart rate 73.6±7.7min-1, R-R 822.7±86.4 ms) (5 men, 22 women) (p<0.001). The VCG measured spatial QRS-STT angle was more opened (70.3±24.5°) than in the control group (49.5±19.5°) (p<0.05). The maximum (extremum) in depolarization (DIAM max 30, 40) and repolarization (RIAM max 35) of body surface isoarea and isointegral (RIIM max) maps was less positive (p<0.001) and the minimum (DIAM min 40) was less negative than in the controls (p<0.05) even in the period free of a panic attack. Our results showed the changes in the heart electric field parameters occurred in PD patients when compared to the control group., K. Pišvejcová, I. Paclt, J. Slavíček, O. Kittnar, A. Dohnalová, E. Kitzlerová., and Obsahuje bibliografii
Gestational diabetes mellitus (GDM) represents additional risks to both mother and infant. Moreover it increases a woman's risk of cardiovascular disease in the postpartum. The aim of our study was therefore to detect changes of both the QT dispersion and the electrical heart field that could be typical for GDM. Body surface potential maps were obtained using the Cardiac 112.2 device from 26 young women with GDM and 54 young healthy pregnant women in the 36th week of pregnancy. The same recordings were obtained from 18 healthy women in the same age (19-36 years). The average QT dispersion (±SD) in women suffering from GDM was significantly higher (107±25 ms) both than in those with physiological pregnancy (73±18 ms) and than in the normal subjects (34±12 ms) (P<0.001). Moreover we have found in GDM patients shorter QRS complex 82.0±6.8 ms vs. 89.5±8.2 ms in healthy pregnant women and 90.8±7.9 ms in the control group (p=0.011), more horizontal electrical heart axis [16.4±20.1° vs. 42.4±28.7° and 74.6±39.2° respectively (P<0.05)] and lower some depolarization and repolarization amplitudes on isopotential and isointegral maps. According to these results we suppose that described electrocardiographic changes reflect a deterioration of the complete process of ventricular depolarization and repolarization in GDM., E. Medová, ... [et al.]., and Obsahuje seznam literatury