The aims were to explore the effect of head-up tilt (HUT) to 30 and 60 degrees on hemodynamics and tissue oxygenation in anesthetized healthy swine. The data serve as a reference for a study of resuscitation efficacy at HUT such as during transport. Nine healthy swine (49±4 kg) were anesthetized and multiple sensors including myocardial pressure-volume loops catheter, carotid flow probe, blood pressure catheters, near infrared spectroscopy (NIRS) tissue oximetry and mixed venous oximetry (SVO2) catheter were introduced and parameters continuously recorded. Experimental protocol consisted of baseline in supine position (15 min), 30 degrees HUT (15 min), recovery at supine position (15 min) and 60 degrees HUT (5 min). Vacuum mattress was used for body fixation during tilts. We found that 30 and 60 degrees inclination led to significant immediate reduction in hemodynamic and oximetry parameters. Mean arterial pressure (mm Hg) decreased from 98 at baseline to 53 and 39, respectively. Carotid blood flow dropped to 47 % and 22 % of baseline values, end diastolic volume to 49 % and 53 % and stroke volume to 47 % and 45 % of baseline. SVO2 and tissue oximetry decreased by 17 and 21 percentage points. The values are means. In conclusions, within minutes, both 30 and 60 degrees head-up tilting is poorly tolerated in anesthetized swine. Significant differences among individual animals exist., M. Mlcek, J. Belohlavek, M. Huptych, T. Boucek, T. Belza, S. Lacko, P. Krupickova, M. Hrachovina, M. Popkova, P. Neuzil, O. Kittnar., and Obsahuje bibliografii
Early recognition of collapsing hemodynamics in pulmonary embolism is necessary to avoid cardiac arrest using aggressive medical therapy or mechanical cardiac support. The aim of the study was to identify the maximal acute hemodynamic compensatory steady state. Overall, 40 dynamic obstructions of pulmonary artery were performe d and hemodynamic data were collected. Occlusion of only left or right pulmonary artery did not lead to the hemodynamic collapse. When gradually obstructing the bifurcation, the right ventri cle end-diastolic area expanded proportionally to pulmonary artery mean pressure from 11.6 (10.1, 14.1) to 17.8 (16.1, 18.8) cm 2 (p<0.0001) and pulmonary artery mean pressure increased from 22 (20, 24) to 44 (41, 47) mmHg (p<0.0001) at the poin t of maximal hemodynamic compensatory steady state. Sim ilarly, mean arte rial pressure decreased from 96 (87, 101) to 60 (53, 78) mmHg (p<0.0001), central venous pressure increased from 4 (4, 5) to 7 (6, 8) mmHg (p<0.0001), heart rate increased from 92 (88, 97) to 147 (122, 165) /min (p<0.0001), contin uous cardiac output dropped from 5.2 (4.7, 5.8) to 4.3 (3.7, 5.0) l/min (p=0.0023), modified shock index increased from 0.99 (0.81, 1.10) to 2.31 (1.99, 2.72), p<0.0001. In conclusion, in stead of continuous cardiac output all of the analyzed parameters can sensitively determine the individual maximal compensatory response to obstructive shock. We assume their monitoring can be used to predict the critical phase of the hemodynamic status in routine practice., J. Kudlička ... [et al.]., and Obsahuje bibliografii a bibliografické odkazy
The growth in the experimental research of facilities to support extracorporeal circulation requires the further development of models of acute heart failure that can be well controlled and reproduced. Two types of acute heart failure were examined in domestic pigs (Sus scrofa domestica ): a hypoxic model (n=5) with continuous perfusion of the left coronary artery by hypoxic deoxygenated blood and ischemic model (n=9) with proximal closure of the left coronary artery and controlled hypoperfusion behind the closure. The aim was a severe, stable heart pump failure defined by hemodynamic parameters changes: a) decrease in cardiac output by at least 50 %; b) decrease in mixed venous blood saturation to under 60 %; c) left ventricular ejection fraction below 25 %; and d) decrease in flow via the carotid arteries at least 50 %. Acute heart failure developed in the first group in one animal with no acute mortality and in the second group in 8 animals with no acute mortality. In the case of ischemic model the cardiac output fell from 6.70±0.89 l/min to 2.89±0.75 l/min. The saturation of the mixed venous blood decreased from 83±2 % to 58±8 %. The left ventricular ejection fraction decreased from 50±8 % to 19±2 %. The flow via the carotid arteries decreased from 337±78 ml/min to 136±59 ml/min (P≤0.001 for all comparisons). The proposed ischemic model is not burdened with acute mortality in the development of heart failure and is suitable for further use in experimental research into extracorporeal circulatory support., S. Lacko, M. Mlček, P. Hála, M. Popková, D. Janák, M. Hrachovina, J. Kudlička, V. Hrachovina, P. Ošťádal, O. Kittnar., and Obsahuje bibliografii