Selective serotonine reuptake inhibitors (SSRI) are believed to be less dangerous in the treatment of depressive disorder in comparison with tricyclic antidepressants (TCA) due to their relative lack of cardiotoxicity. Thus, we investigated the effect of citalopram (SSRI) on membrane electrophysiology in rat cardiomyocytes in tissue culture. The results were compared with those from amitriptyline (TCA). The whole-cell configuration patch-clamp technique was used. Both citalopram and amitriptyline exhibited the concentration-dependent inhibition of the L-type calcium channel current (ICa). Citalopram in concentrations of 3 mM and 10 mM inhibited peak calcium current by 2.7 % and 8 %, respectively. We demonstrated the same potency of citalopram and amitriptyline to inhibit ICa. These observations led us to conclude that citalopram and amitriptyline are drugs, which exhibit a similar potency for causing concentration-dependent inhibition of ICa., J. Hamplová-Peichlová, J. Krůšek, I. Paclt, J. Slavíček, V. Lisá, F. Vyskočil., and Obsahuje bibliografii
a1_Diabetes mellitus is a risk factor of cardiovascular diseases. ECG of patients with diabetes mellitus type 1 (DM 1) shows tachycardia (block of parasympathetic innervation) and abnormal repolarization (increased QT interval and QT dispersion (QTd)) indicating a risk of ventricular tachycardia and sudden death in young people with DM 1. The aim of the present report was to measure 145 parameters of the heart electric field in 22 patients (14 men, 8 women) with DM 1 without complications (mean age 32.8±11.4 years) and in 22 controls (11 men, 11 women, mean age 30.1±3.4 years). The duration of diabetes was 13.9 ±7.8 years. The parameters were regist ered by the diagnostic system Cardiag 112.2 and statistically evaluated by the Student and Mann-Whitney test. Tachycardia (86.3±2.7 beats.min-1), shortening of both QRS (79.9±1.6 ms) and QT (349.0±5.9 ms) and increased QT dispersion (115±36 ms) were observed in DM 1 when compared with the controls (75.0±2.1 beats. min -1, QRS 89.9±2.7 ms, QT 374.0±4.4 ms, QTd 34.0±12.0 ms, p<0.01). The QTc was 415.2±4.1 ms in DM 1 and 401.4±6.6 ms in controls (NS)., a2_Other significant findings in DM 1 were: higher maximum of depolarization isopotential maps (DIPMmax) in the initial phase of QRS and less positive in the terminal phase, more negative minimum (DIPMmin) during QRS similarly as the minimum in depolarization isointegral maps (DIIMmin) and the minimum in isointegral map of the Q wave (Q-IIMmin), lower maximum in repolarization isopotential maps (RIPMmax) and less negative minimum (RIPMmin), more negative amplitude of Q wave (Q-IPMAM) and more pronounced spread of depolarization (activation time). Our results confirmed a decreased parasympathetic to sympathetic tone ratio (tachycardia, shortening of the activation time) and revealed different depolarization and repolarization patterns in DM 1. The differences in heart electric field parameters measured by the BSPM method in DM 1 and in the controls indicate the importance of ECG examination of diabetic patients type 1 in the prevention of cardiovascular diseases., D. Žďárská, P. Pelíšková, J. Charvát, J. Slavíček, M. Mlček, E. Medová, O. Kittnar., and Obsahuje bibiografii a bibliografické odkazy
An increased risk of myocardial ischemic changes was demonstrated in patients suffering from panic disorder (PD). Using classical ECG methods, this risk cannot be evaluated in most patients. We measured the vectocardiogram (VCG) using Frank orthogonal leads and body surface maps (BSM) including 12-lead ECG. In our study of 11 PD patients (2 men, 9 women), without any seizures and pharmacological treatment and without cardiovascular symptoms, we found marked sinus tachycardia (heart rate 90.1±12.2 min-1) and a shorter R-R interval (678±93.6 ms) than in 27 controls (heart rate 73.6±7.7min-1, R-R 822.7±86.4 ms) (5 men, 22 women) (p<0.001). The VCG measured spatial QRS-STT angle was more opened (70.3±24.5°) than in the control group (49.5±19.5°) (p<0.05). The maximum (extremum) in depolarization (DIAM max 30, 40) and repolarization (RIAM max 35) of body surface isoarea and isointegral (RIIM max) maps was less positive (p<0.001) and the minimum (DIAM min 40) was less negative than in the controls (p<0.05) even in the period free of a panic attack. Our results showed the changes in the heart electric field parameters occurred in PD patients when compared to the control group., K. Pišvejcová, I. Paclt, J. Slavíček, O. Kittnar, A. Dohnalová, E. Kitzlerová., and Obsahuje bibliografii
The aim of the study was to detect changes of both the QT dispersion and T-loop morphology resulting from the changed spatial position of the heart during pregnancy. Electrocardiographic and vectorcardiographic recordings were obtained from 37 healthy women 19-36 years old in the 36th to 40th week of physiological pregnancy and 2 to 6 days after delivery. The same recordings were obtained from 18 healthy women of the same age. The average QT dispersion (±S.D.) in normal subjects was significantly lower (34±12 ms) than in those in late pregnancy (73±18 ms) (P<0.001). The average amplitude of T-loop (Ta) in women in late pregnancy was significantly (P<0.001) smaller (532±98 mV) and the width of T-loop (Tw) was wider (21.24±11.48 deg) than in the control group (793±114 mV and 7.17±3.02 deg, respectively). The partial post-partum restoration of all parameters was not significant. In all groups, the QT dispersion was significantly correlated with Tw but not with Ta. According to these results we can conclude that the QT dispersion is an indirect reflection of the complete process of ventricular repolarization, reflected in the morphology of the T-loop., M. Lechmanová, O. Kittnar, M. Mlček, J. Slavíček, A. Dohnalová, Š. Havránek, J. Kolařík, A. Pařízek., and Obsahuje bibliografii