The European Academies Science Advisory Council was formed by the national science academies of EU Member States to enable them to collaborate with each other in providing advice to European policy-makers. It thus offers the means for the collective voice of European science to be heard. The EASAC covers all scientific and technical disciplines, and its experts are drawn from all coutries of the European Union. The most recent EASAC meeting was held in June 2008 in Prague. and Luděk Svoboda, Gabriela Adámková.
Commercial chambers for in vivo gas exchange are usually designed to measure on vascular plants, but not on cryptogams and other organisms forming biological soil crusts (BSCs). We have therefore designed two versions of a chamber with different volumes for determining CO2 exchange with a portable photosynthesis system, for three main purposes: (1) to measure in situ CO2 exchange on soils covered by BSCs with minimal physical and microenvironmental disturbance; (2) to acquire CO2-exchange measurements comparable with the most widely employed systems and methodologies; and (3) to monitor CO2 exchange over time. Different configurations were tested in the two versions of the chamber and fluxes were compared to those measured by four reference commercial chambers: three attached to two respirometers, and a conifer chamber attached to a portable photosynthesis system. Most comparisons were done on biologically crusted soil samples. When using devices in a closed system, fluxes were higher and the relationships to the reference chambers were weaker. Nevertheless, high correlations between our chamber operating in open system and measurements of commercial respiration and photosynthetic chambers were found in all cases (R2 > 0.9), indicating the suitability of the chamber designed for in situ measurements of CO2 gas exchange on BSCs., M. Ladrón De Guevara, R. Lázaro, J. L. Quero, S. Chamizo, F. Domingo., and Obsahuje bibliografii
klavírní part s vepsaným textem (2 strany), (Ownership) Provenience: Wendelin Tögel, 1868, Klášter minoritů Český Krumlov CZ-CbJVK, and (Version Identification) bez značek CZ-CbJVK
a1_Diabetes mellitus is a risk factor of cardiovascular diseases. ECG of patients with diabetes mellitus type 1 (DM 1) shows tachycardia (block of parasympathetic innervation) and abnormal repolarization (increased QT interval and QT dispersion (QTd)) indicating a risk of ventricular tachycardia and sudden death in young people with DM 1. The aim of the present report was to measure 145 parameters of the heart electric field in 22 patients (14 men, 8 women) with DM 1 without complications (mean age 32.8±11.4 years) and in 22 controls (11 men, 11 women, mean age 30.1±3.4 years). The duration of diabetes was 13.9 ±7.8 years. The parameters were regist ered by the diagnostic system Cardiag 112.2 and statistically evaluated by the Student and Mann-Whitney test. Tachycardia (86.3±2.7 beats.min-1), shortening of both QRS (79.9±1.6 ms) and QT (349.0±5.9 ms) and increased QT dispersion (115±36 ms) were observed in DM 1 when compared with the controls (75.0±2.1 beats. min -1, QRS 89.9±2.7 ms, QT 374.0±4.4 ms, QTd 34.0±12.0 ms, p<0.01). The QTc was 415.2±4.1 ms in DM 1 and 401.4±6.6 ms in controls (NS)., a2_Other significant findings in DM 1 were: higher maximum of depolarization isopotential maps (DIPMmax) in the initial phase of QRS and less positive in the terminal phase, more negative minimum (DIPMmin) during QRS similarly as the minimum in depolarization isointegral maps (DIIMmin) and the minimum in isointegral map of the Q wave (Q-IIMmin), lower maximum in repolarization isopotential maps (RIPMmax) and less negative minimum (RIPMmin), more negative amplitude of Q wave (Q-IPMAM) and more pronounced spread of depolarization (activation time). Our results confirmed a decreased parasympathetic to sympathetic tone ratio (tachycardia, shortening of the activation time) and revealed different depolarization and repolarization patterns in DM 1. The differences in heart electric field parameters measured by the BSPM method in DM 1 and in the controls indicate the importance of ECG examination of diabetic patients type 1 in the prevention of cardiovascular diseases., D. Žďárská, P. Pelíšková, J. Charvát, J. Slavíček, M. Mlček, E. Medová, O. Kittnar., and Obsahuje bibiografii a bibliografické odkazy
Women with gestational diabetes mellitus (GDM) are at increased risk for cardiovascular diseases (CVD) events compared with women without GDM. The aim of the present study was to evaluate 200 parameters of the heart electric field in 35 women with GDM under optimal glycemic compensation compared to 32 healthy pregnant women. All examinations were performed in the 36th week of gestation. The parameters in ECG body surface mapping (BSM) were registered by the diagnostic system Cardiag 112.2. The absolute values of maximum and minimum in depolarization and repolarization isopotential, isointegral and isoarea maps were not significantly different between the groups. These findings correspond to the result of heart rate variability examination. However BSM revealed the significant prolongation of QRS complex (p=0.05), shortening of ventricular myocardial activation time (ICHVAT) (p=0.01), prolongation of mean QT duration (p=0.01) and increase of QT interval dispersion (p=0.01) in women with GDM. Duration of QRS and ICHVAT significantly correlated with interventricular septum and posterior wall thickness in GDM group, QTd interval correlated significantly with HbA1C level. We conclude that despite of optimal metabolic control several significant abnormalities detected by ECG BSM are still present in patients with GDM., E. Žákovičová, O. Kittnar, J. Slavíček, E. Medová, P. Šváb, J. Charvát., and Obsahuje bibliografii