Inflammation and other immune responses are involved in the variety of diseases and disorders. The acute response to endotoxemia includes activation of innate immune mechanisms as well as changes in autonomic nervous activity. The autonomic nervous system and the inflammatory response are intimately linked and sympathetic and vagal nerves are thought to have anti-inflammation functions. The basic functional circuit between vagus nerve a nd inflammatory response was identified and the neuroimmunomodulation loop was called cholinergic anti-inflammatory pathway. Unique function of vagus nerve in the anti-inflammatory reflex arc was found in many experimental and pre-clinical studies. They br ought evidence on the cholinergic signaling interacting with systemic and local inflammation, particularly suppressing immune cells function. Pharmacological/electrical modulation of vagal activity suppressed TNF-α and other proinflammatory cytokines prod uction and had beneficial therapeutic effects. Many questions related to mapping, linking and targeting of vagal-immune interactions have been elucidated and brought understanding of its basic physiology and provided the initial support for development of Tracey's inflammatory reflex. This review summarizes and critically assesses the current knowledge defining cholinergic anti-inflammatory pathway with main focus on studies employing an experimental approach and emphasizes the potential of modulation of va gally-mediated anti-inflammatory pathway in the treatment strategies., I. Zila, D. Mokra, J. Kopincova, M. Kolomaznik, M. Javorka, A. Calkovska., and Obsahuje bibliografii
The aim of this study was to assess the performance of several approximation techniques for ionospheric total electron content (TEC) mapping. Approximation techniques based on data-fitting with local or general two-dimensional polynomials, local planes or distance-dependent interpolation were applied and tested. For the ionosphere modeling, dual-frequency GPS data from Polish GBAS system (ASG-EUPOS) were used, and TEC was estimated together with hardware delays from phasesmoothed pseudoranges. Next, grids of vertical TEC values with spatial resolution of 0.25 degrees in both latitude and longitude were generated using the evaluated approximation techniques. Subsequently the grids were used to create regional TEC maps with 5-minute temporal resolution, and also to create ionospheric delay corrections for GPS positioning. The quality of the resulting ionospheric maps was tested twofold, firstly by comparison to high-quality CODE global ionosphere maps (GIM), which were generated using data from about 150 GPS sites of the International GNSS Service (IGS). Secondly, by creating double-differenced ionospheric delay corrections and comparing them to reference values derived from the reference network data processing. For the correction tests, two perpendicular baselines directed North-South (N-S) and West-East (W-E) and reaching up to 100 km were selected. The approximation methods were analyzed with a special emphasis on the diverse ionospheric conditions. For the testing, a quiet ionosphere day of 20 March 2012 and an active ionosphere day of 9 March 2012 were selected. The results show that the regional models properly represent the changing ionosphere, with the best results provided by data-fitting into local functions., Anna Krypiak-Gregorczyk, Pawel Wielgosz, Dariusz Gosciewski and Jacek Paziewski., and Obsahuje bibliografii
Mediator is a multiprotein complex that connects regulation mediated by transcription factors with RNA polymerase II transcriptional machinery and integrates signals from the cell regulatory cascades with gene expression. One of the Mediator subunits, Mediator complex subunit 28 (MED28), has a dual nuclear and cytoplasmic localization and function. In the nucleus, MED28 functions as part of Mediator and in the cytoplasm, it interacts with cytoskeletal proteins and is part of the regulatory
cascades including that of Grb2. MED28 thus has the potential to bring cytoplasmic regulatory interactions towards the centre of gene expression regulation. In this study, we identified MDT-28, the nematode orthologue of MED28, as a likely target of lysine acetylation using bioinformatic prediction of post-translational modifications. Lysine acetylation was experimentally confirmed using anti-acetyl lysine antibody on immunoprecipitated GFP::MDT-28 ex-pressed in synchronized C. elegans. Valproic acid (VPA), a known inhibitor of lysine deacetylases, enhanced the lysine acetylation of GFP::MDT-28. At the subcellular level, VPA decreased the nuclear localization of GFP::MDT-28 detected by fluorescence-lifetime imaging microscopy (FLIM). This indicates that the nuclear pool of MDT-28 is regulated by a mechanism sensitive to VPA and provides an indirect support for a variable relative proportion of MED28 orthologues with other Mediator subunits. and Corresponding author: Markéta Kostrouchová
This study investigated the value of oxygen (O2) pulse curves obtained during cardiopulmonary exercise testing (CPET) for the diagnosis of coronary artery disease (CAD). Forty patients with known coronary anatomy (35.0 % normal, 27.0 % single-vessel and 38.0 % multivessel CAD) underwent CPET with radiotracer injection at peak exercise, followed by myocardial scintigraphy. O2 pulse curves were classified as: A-normal, B-probably normal (normal slope with low peak value); C-probably abnormal (flat, with low peak value); or D- definitely abnormal (descending slope). Sensitivity, specificity, positive and negative predictive values of the O2 pulse curve pattern (A or B vs. C or D) for the diagnosis of CAD were, respectively, 38.5 %, 81.3 %, 76.9 %, and 44.8 %. The concordance rate between the abnormal O2 pulse curve pattern and ischemia in myocardial scintigraphy was 38.1 %. Age and the extent of scintigraphic perfusion defect, but not the abnormal O2 pulse curve patterns (B or C or both combined) were independently associated with CAD. In conclusion, the O2 pulse curve pattern has low diagnostic performance for the diagnosis of obstructive CAD, and the abnormal curve pattern was not associated with myocardial ischemia defined by scintigraphy., A. De Lorenzo, C. L. Da Silva, F. C. Castro Souza, R. De Souza Leão Lima., and Obsahuje bibliografii