The 24-hour periodicity of supraventricular (SVPB) and ventricular (VEB) extrasystoles in healthy elderly men (age 49-69 years) was studied at two altitudes during 24 h Holter ECG monitoring. At the low altitude (200 m, n = 26), SVPB were more frequent than VEB. The highest occurrence of SVPB was at 17:00 h, the lowest at 01:00 and 02:00 h (P<0.001). The highest occurrence of VEB was at 09:00 h, the lowest one at 04:00 h (P<0.001). At 1350 m (n=9) the incidence of both SVPB and VEB was approximately twofold higher compared to that at the low altitude (P<0.001). The highest occurrence of SVPB was at 13:00 h, the lowest at 06:00 h (P<0.001). VEB were the most frequent at 10:00 h and 13:00 h, while the lowest frequency was observed at 06:00 h (P<0.001). Our results indicate that the incidence of SVPB and VEB in healthy persons at the moderate altitude is twofold and its periodicity is shifted compared to the low altitude. The cause of increased occurrence of extrasystoles is probably due to β-adrenergic activation of the heart at the higher altitude., Š. Kujaník, M. Sninčák, J.Vokáľ, J. Podracký, J. Koval., and Obsahuje bibliografii
Gestational diabetes mellitus (GDM) represents additional risks to both mother and infant. Moreover it increases a woman's risk of cardiovascular disease in the postpartum. The aim of our study was therefore to detect changes of both the QT dispersion and the electrical heart field that could be typical for GDM. Body surface potential maps were obtained using the Cardiac 112.2 device from 26 young women with GDM and 54 young healthy pregnant women in the 36th week of pregnancy. The same recordings were obtained from 18 healthy women in the same age (19-36 years). The average QT dispersion (±SD) in women suffering from GDM was significantly higher (107±25 ms) both than in those with physiological pregnancy (73±18 ms) and than in the normal subjects (34±12 ms) (P<0.001). Moreover we have found in GDM patients shorter QRS complex 82.0±6.8 ms vs. 89.5±8.2 ms in healthy pregnant women and 90.8±7.9 ms in the control group (p=0.011), more horizontal electrical heart axis [16.4±20.1° vs. 42.4±28.7° and 74.6±39.2° respectively (P<0.05)] and lower some depolarization and repolarization amplitudes on isopotential and isointegral maps. According to these results we suppose that described electrocardiographic changes reflect a deterioration of the complete process of ventricular depolarization and repolarization in GDM., E. Medová, ... [et al.]., and Obsahuje seznam literatury
The long-term electrocardiographic recording with retrospective evaluation (Holter system) has been widely used not only in cardiology, but also in other disciplines of internal medicine and in pharmaceutical research. The Holter system can be used in mini-pig, sheep, dog, cat, rabbit, ferret, and rat. In this paper hardware, software, and anesthesia requirements are summarized with respect to the experimental work with various species. As the Holter systems work in bipolar mode, the use of bipolar leads in sagittal and transversal planes has been proved to be the most appropriate because of large amplitude of QRS complex and uncomplicated consequent automatic analysis of the record. In conclusion, Holter electrocardiography represents a simple and applicable method for monitoring the electrical activity of the heart in small animals’ experimental studies., P. Scheer ... [et al.]., and Obsahuje bibliografii a bibliografické odkazy
The Frank orthogonal corrected ECG and its first derivation were recorded in 27 healthy volunteers (women aged 19-22 years) during normal ventilation at rest (control group), after voluntary hyperventilation lasting 75 seconds, and during hypoxic-hypercapnic ventilation (through the enlarged dead space) lasting 5 min. The projections of the magnitude and direction of the positive and negative QRS derivation maxima into the horizontal, frontal, left sagittal planes and their spatial distribution were constructed. The magnitude of the positive and negative QRS derivation maxima was significantly decreased during hypoxic-hypercapnic ventilation. A significant alteration in the direction only arose at the positive maximum during hypoxic-hypercapnic ventilation in the frontal plane. The intrinsicoid deflection was not significantly altered. The normal values of the maxima of the first QRS derivation in young healthy women are given. It is supposed that the decrease in amplitude of the maxima of the first QRS derivation is caused by slowed propagation of the depolarization wave under hypoxic- hypercapnic conditions and alteration of the direction of the positive maximum is caused by a greater participation of the right ventricle at the origin of the resulting QRS vector.
A brief description of the methodology of analysis of the electric heart field using electrocardiograms, vectorcardiograms, diagrams of potential maxima/minima and body surface potential maps is presented. The text is focused on the description of different kinds of isopotential and isointegral maps and their diagnostic possibilities. A detailed description of the diagram of potential maxima/minima and its place in diagnostic of different disturbances of the heart muscle and conduction defects is given.
The influence of some pulmonary ventilation alterations (the normal ventilation at rest = control), the hyperventilation (HV) lasting 75 s, the hypoxic-hypercapnic ventilation (HXV) lasting 3 and 6 min) on the instantaneous QRS vectors was investigated in 42 young healthy women (19-24 years old). The magnitude and the direction of instantaneous QRS vectors in the 10th to the 70th ms and in QRS max were constructed from the Frank lead ECG. The significant alterations of the direction (angle) were found in the 30th ms and QRS max at HXV and in the 60th ms at HV. A significant decrease in the magnitude of instantaneous vectors was found in the 10th to 50th ms after 6 min of HXV, in the 30th to 50th ms at 3 min of HXV, in the 40th to 50th ms at HV. These alterations were the most marked in the horizontal plane. We suggest that the alterations of the instantaneous QRS vectors were caused by the influence of the autonomic nervous system or humoral agents, but not by heart position, Brody’s effect or lung hyperinflation.
Aims of the study were to compare the development of electrocardiographic responses of the ischemia-induced heterogeneities of activation and repolarization in the ventricular myocardium of normal and diabetic animals. Body surface ECGs and unipolar electrograms in 64 epicardial leads were recorded before and during 20 min after the ligation of the left anterior descending artery in diabetic (alloxan model, 4 weeks, n=8) and control (n=8) rabbits. Activation times (ATs), end of repolarization times (RTs) and repolarization durations (activation-recovery intervals, ARIs) were determined in ischemic and periischemic zones. In contrast to the controls, the diabetic rabbits demonstrated the significant prolongation of ATs and shortening of ARIs (P<0.05) during ischemia in the affected region resulting in the development and progressive increase of the ARI and RT gradients across the ischemic zone boundary. The alterations of global and local dispersions of the RTs in diabetics correlated with the Tpeak-Tend interval changes in the limb leads ECGs. In the ischemic conditions, the diabetic animals differed from the controls by the activation delay, significant repolarization duration shortening, and the increase of local repolarization dispersion; the latter could be assessed by the Tpeak-Tend interval measurements in the body surface ECGs., K. A. Sedova, M. A. Vaykshnorayte, A. O. Ovechkin, P. Kneppo, O. G. Bernikova, V. A. Vityazev, J. E. Azarov., and Obsahuje bibliografii