Transthoracic echocardiography (TTE) has become an important modality for the assessment of cardiac structure and function in animal experiments. The acquisition of echocardiographic images in rats requires sedation/anesthesia to keep the rats immobile. Commonly used anesthetic regimens include intraperitoneal or inhalational application of various anesthetics. Several studies have compared the effects of anesthetic agents on echocardiographic parameters in rats; however, none of them examined the effects of different concentrations of inhalational anesthetics on echocardiographic parameters. Accordingly, the aim of this study was to examine the effects of different concentrations of isoflurane used for anesthesia during TTE examination in rats on basic echocardiographic parameters of left ventricular (LV) anatomy and systolic function. TTE examinations were performed in adult male Wistar rats (n=10) anesthetized with isoflurane at concentrations of 1.5-3 %. Standard echocardiograms were recorded for off-line analysis. An absence of changes in basic echocardiographic parameters of LV anatomy and systolic function was found under isoflurane anesthesia using concentrations between 1.5-2.5 %. An isoflurane concentration of 3 % caused a small, but statistically significant, increase in LV chamber dimensions without a concomitant change in heart rate or fractional shortening. For the purpose of TTE examination in the rat, our results suggest that isoflurane concentrations ≤ 2.5 % can be safely recommended., H. Říha ... [et al.]., and Obsahuje seznam literatury
Respiration changes intrathoracic pressure and lung volumes in a cyclic manner, which affect cardiac function. Invasive ventricular pressure-volume (PV) loops can be recorded during ongoing mechanical ventilation or in transient apnea. No consensus exists considering ventilatory mode during PV loop recording. The objective of this study was to investigate the magnitude of any systematic difference of bi-ventricular PV loop variables recorded during mechanical ventilation versus apnea. PV loops were recorded simultaneously from the right ventricle and left ventricle in a closed chest porcine model during mechanical ventilation and in transient apnea (n=72). Variables were compared by regression analyses. Mechanical ventilation versus apnea affected regression coefficients for important PV variables including right ventricular stroke volume (1.22, 95% CI [1.08-1.36], p=0.003), right ventricular ejection fraction (0.90, 95% CI [0.81-1.00], p=0.043) and right ventricular arterial elastance (0.61, 95%CI [0.55-0.68], p<0.0001). Right ventricular pressures and volumes were parallelly shifted with Y-intercepts different from 0. Few left ventricular variables were affected, mainly first derivatives of pressure (dP/dt(max): 0.96, 95% CI [0.92-0.99], p=0.016, and dP/dt(min): 0.92, 95% CI [0.86-0.99], p=0.026), which might be due to decreased heart rate in apnea (Y-intercept -6.88, 95% CI [-12.22; -1.54], p=0.012). We conclude, that right ventricular stroke volume, ejection fraction and arterial elastance were mostly affected by apnea compared to mechanical ventilation. The results motivate future standardization of respiratory modality when measuring PV relationships.