The vibration plethysmographic method of arterial compliance analysis in dependence on transmural pressure
- Title:
- The vibration plethysmographic method of arterial compliance analysis in dependence on transmural pressure
- Creator:
- Jiří Moudr, Jitka Svačinová, Eva Závodná, and Nataša Honzíková
- Identifier:
- https://cdk.lib.cas.cz/client/handle/uuid:9f5b852d-97ba-4039-84ee-bf9cc5ccb82c
uuid:9f5b852d-97ba-4039-84ee-bf9cc5ccb82c
issn:0862-8408 - Subject:
- Fyziologie člověka a srovnávací fyziologie, tepny, krevní tlak, arteries, blood pressure, arterial compliance, finger arterial pressure, plethysmography, transmural arterial pressure, frequency characteristic, 14, and 612
- Type:
- article, články, model:article, and TEXT
- Format:
- print, bez média, and svazek
- Description:
- The aim of this study was to obtain a detailed analysis of the relationship between the finger arterial compliance C [ml/mm Hg] and the arterial transmural pressure Pt [mm Hg]. We constructed a dynamic plethysmograph enabling us to set up a constant pressure Pcss [mm Hg] and a superimposed fast pressure vibration in the finger cuff (equipped with a source of infra-red light and a photoelectric sensor for the measurement of arterial volume). Pcss could be set on the required time interval in steps ranging between 30 and 170 mm Hg, and on sinusoidal pressure oscillation with an amplitude Pca (2 mm Hg) and a frequency f (20, 25, 30, 35, 40 Hz). At the same time continuous blood pressure BP was measured on the adjacent finger (Portapres). We described the volume dependence of a unitary arterial length on the time-varying transmural pressure acting on the arterial wall (externally Pcss+Pca.sin(2πf), internally BP) by a second-order differential equation for volume. This equation was linearized within a small range of selected BP. In the next step, a Fourier transform was applied to obtain the frequency characteristic in analytic form of a complex linear combination of frequency functions. While series of oscillations [Pca, f] were applied for each Pcss, the corresponding response of the plethysmogram was measured. Amplitude spectra were obtained to estimate coefficients of the frequency characteristic by regression analysis. We determined the absolute value: elastance E, and its inverse value: compliance (C=1/E). Then, C=C(Pt) was acquired by applying sequences of oscillations for different Pcss (and thus Pt) by the above-described procedure. This methodology will be used for the study of finger arterial compliance in different physiological and pathological conditions., J. Moudr, J. Svačinová, E. Závodná, N. Honzíková., and Obsahuje bibliografii
- Language:
- English
- Rights:
- http://creativecommons.org/licenses/by-nc-sa/4.0/
policy:public - Source:
- Physiological research | 2014 Volume:63 | Number:Suppl 4
- Harvested from:
- CDK
- Metadata only:
- false
The item or associated files might be "in copyright"; review the provided rights metadata:
- http://creativecommons.org/licenses/by-nc-sa/4.0/
- policy:public