INTRODUCTION: A previous study has employed shear-wave ultrasound elastographic imaging to assess corneal rigidity in an ex-vivo porcine eye model. This study employs the same modality in vivo in a rabbit eye model in order to assess lens, ciliary body and total ocular rigidity changes following the instillation of atropine and pilocarpine. METHODS: Ten non-pigmented female rabbits were examined. Measurements of the lens, ciliary body and total ocular rigidity as well as lens thickness and anterior chamber depth were taken with the Aixplorer system (SuperSonic Imagine, Aix-en-Provence, France) with the SuperLinear™ SL 15-4 transducer in both eyes at baseline as well as after pilocarpine and atropine instillation. The IOP was also measured with the TonoPen tonometer. RESULTS: Changes in rigidity in the examined areas following atropine instillation were statistically not significant. Ciliary body rigidity was significantly increased whereas lens and total ocular rigidity were significantly reduced following pilocarpine instillation. The decrease in lens rigidity following pilocarpine was significantly associated with the respective increase in ciliary body rigidity. CONCLUSIONS: Shear-wave ultrasound elastography can detect in vivo rigidity changes in the anterior segment of the rabbit eye model and may potentially be applied in human eyes, providing useful clinical information on conditions in which rigidity changes play an important role, such as glaucoma, pseudoexfoliation syndrome or presbyopia. and E. T. Detorakis, E. E. Drakonaki, H. Ginis, N. Karyotakis, I. G. Pallikaris
PURPOSE: A variety of anti-glaucomatous shunt designs have been proposed so far. This study evaluates the feasibility of a novel shunt design, the intra-scleral parathalamus implant (IPI), in a rabbit eye model. METHODS: Ten healthy albino rabbits were included. Measurements of the IOP, using TonoPenXL, as well as ocular rigidity (OR) and aqueous outflow facility (AO), using a previously described methodology, were performed in both eyes of each animal. Subsequently, the IPI was implanted at the left eye of all animals whereas the right eye served as control. Measurements of IOP were repeated at weekly intervals for 2 months postoperatively whereas measurements of OR and AO were repeated at the 1st and 2nd postoperative week. RESULTS: The IOP decreased significantly whereas the AO increased significantly postoperatively at the operated eyes. A significant postoperative decrease in OR was also recorded at the operated eyes. Respective differences at the fellow eyes were statistically not significant. Two animals developed postoperative complications and were excluded from follow-up. CONCLUSIONS: Results imply that the implantation of the IPI is feasible in rabbit eyes with significant favorable effects on the IOP, AO and OR. and E. T. Detorakis, K. Loggaki, N. Karyotakis, H. Ginis
PURPOSE: Taking into account the fact that Goldmann applanation tonometry (GAT) geometrically deforms the corneal apex and displaces volume from the anterior segment whereas Dynamic Contour Tonometry (DCT) does not, we aimed at developing an algorithm for the calculation of ocular rigidity (OR) based on the differences in pressure and volume between deformed and non-deformed status according to the general Friedenwald principle of differential tonometry. METHODS: To avoid deviations of GAT IOP from true IOP in eyes with corneas different from the "calibration cornea" we applied the previously described Orssengo-Pye algorithm to calculate an error coefficient "C/B". To test the feasibility of the proposed model, we calculated the OR coefficient (r) in 17 cataract surgery candidates (9 males and 8 females). RESULTS: The calculated r according to our model (mean ± SD, range) was 0.0174 ± 0.010 (0.0123-0.022) mmHg/μL. A negative statistically significant correlation between axial length and r was detected whereas correlations between r and other biometric parameters examined were statistically not significant. CONCLUSIONS: The proposed method may prove a valid non-invasive tool for the measurement method of OR, which could help in introducing OR in the decision-making of the routine clinical practice. and E. T. Detorakis, E. Tsaglioti, G. Kymionis
Sometimes intraorbital foreign bodies lead to unexpected findings. A 16-year old boy was referred due to ocular surface trauma. A conjunctival laceration was detected at the level of the left caruncle with associated left exotropia, reduced adduction as well as a preretinal hemorrhage along the nasal periphery of the fundus. A blow-out fracture of the medial orbital wall was suspected and a CT scan of the orbits was scheduled which revealed the presence of a large intraorbital foreign body. The removal of the intraorbital foreign body (which proved to be a bullet) and precautionary laser photocoagulation along the nasal periphery of the left eye were performed. Ocular surface trauma may reveal unexpected findings, such as an intraorbital foreign body, requiring investigation by a CT scan., Efstathios T. Detorakis, Emmanouil K. Symvoulakis, Eleni Drakonaki, Ekaterini Halkia, Miltiadis K. Tsilimbaris, and Literatura 7