Number of results to display per page
Search Results
262. Průzkum SÚKL: Léky za více než 1,5 miliardy korun zůstaly nevyužity
- Format:
- braille, text, and regular print
- Type:
- model:article, article, Text, and TEXT
- Subject:
- lidé, systémy pro sběr zpráv o nežádoucích účincích léků, and spotřeba léčiv--ekonomika--statistika a číselné údaje
- Language:
- Czech
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
263. Pseudomyxoma peritonei
- Creator:
- Kocián, Roman
- Format:
- braille, electronic resource, remote, and elektronický zdroj
- Type:
- model:article, article, Text, statistics, and TEXT
- Subject:
- lidé, pseudomyxom peritonea--diagnóza--terapie, nádory apendixu, incidence, ženské pohlaví, mužské pohlaví, recidiva, staging nádorů, popis nemoci, kombinovaná terapie, indukovaná hypotermie, protokoly antitumorózní kombinované chemoterapie, algoritmy, výsledek terapie, smrt, přežití, prognóza, and laparotomie
- Language:
- Czech and English
- Description:
- Pseudomyxoma peritonei je vzácný klinický syndrom; nádorový proces, pro který je charakteristické hromadění mucinózního ascitu a peritoneálních implantátů v břišní dutině. Primárním zdrojem je téměř vždy low grade mucinózní tumor apendixu. Jedná se o pomalu progredující, nízce agresivní, ale smrtící onemocnění s častými recidivami. Optimálním léčebným postupem je kompletní chirurgická cytoredukce (CRS) v kombinaci s peroperačně aplikovanou intraperitoneální hypertermickou chemoterapií (HIPEC) – tzv. Sugarbakerova metoda., Pseudomyxoma peritonei (PMP) is an uncommon clinical syndrome characterized by the slow and progressive accumulation of peritoneal implants and mucinous ascites, intraabdominal gelatinous collection (jelly belly). PMP is reported to originate from the low grade appendiceal mucinous neoplasm. Pseudomyxoma peritonei often recurs after treatment and may eventually cause death by abdominal visceral dysfunction via compression with mucinous ascites. Cytoreductive surgery (CRS) and perioperative intraperitoneal chemotherapy comprising hyperthermic intraperitoneal chemotherapy (HIPEC) with or without postoperative intraperitoneal chemotherapy (EPIC) has been regarded as the standard of care in specialized centers. It is often referred to as the „Sugerbaker procedure“. Conventionally, PMP is considered resistant to systemic chemotherapy. Even though complete cytoreduction is associated with prolonged overall survival, recurrence of disease is common and multiple operations are frequently required. Patients may enjoy sustained period of remission, free of symptoms, but long – term disease free survival is distinctly uncommon. The pathologic subtype remains the dominant factor in survival. Patients should be centralized to improve survival by a combination of surgical experience and adequate patient selection., Roman Kocián, and Literatura
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
264. Psychosomatická medicína ako súčasť modernej medicíny
- Creator:
- Fedor-Freybergh, Peter and Hrubý, Radovan
- Format:
- braille, electronic resource, remote, and elektronický zdroj
- Type:
- model:article, article, Text, statistics, and TEXT
- Language:
- Czech and Slovak
- Description:
- Fedor-Freybergh, P. G., Hrubý R.
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
265. Pyogenní stafylokoková sakroileitida diagnostikovaná pomocí třífázové scintigrafie skeletu
- Creator:
- Širůček, Pavel, Holeszová, Adela, Havel, Martin, and Koscielnik, Pavel
- Format:
- braille, text, and regular print
- Type:
- model:article, article, Text, kazuistiky, and TEXT
- Subject:
- sakroiliitida--diagnóza--mikrobiologie--terapie, bakteriologické techniky--metody--přístrojové vybavení--využití, Staphylococcus aureus--izolace a purifikace, kostra, radioisotopová scintigrafie--metody--přístrojové vybavení--využití, páteř--chirurgie--mikrobiologie--radioizotopová diagnostika, bederní obratle--chirurgie--mikrobiologie--radioizotopová diagnostika, pánev--chirurgie--mikrobiologie--radioizotopová diagnostika, absces--diagnóza--etiologie--chirurgie, antibakteriální látky--terapeutické užití, ortopedické výkony--metody, ženské pohlaví, dítě, and lidé
- Language:
- Czech and English
- Description:
- V naší kazuistice prezentujeme případ 11leté pacientky s akutní bolestí bederní páteře, pánve a proximální části levého stehna. Třífázová scintigrafie skeletu s nálezem zvýšené akumulace 99mTc-hydroxydifosfonátu v levém sakroiliakálním skloubení napomohla k diagnóze levostranné septické sakroileitidy. Hemokultivace byla pozitivní, etiologicky byl zjištěn Staphylococcus aureus. Parenterální antibiotická terapie vedla k poklesu zánětlivých parametrů, snížení bolestivosti. Pro zformování abscesu mezi levou lopatou kosti kyčelní a musculus iliacus byla provedena v celkové anestézii jeho evakuace. Stafylokoková sakroileitida vyžaduje rychlou diagnózu, cílenou antibiotickou terapii a případně chirurgické řešení komplikací., x, Pavel Širůček, Adela Holeszová, Martin Havel, Pavel Koscielnik, and Literatura
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
266. Quod bonum, felix, faustum, fortunatumque sit
- Creator:
- Kříž, Jaroslav
- Format:
- braille, text, and regular print
- Type:
- model:article, article, Text, recenze, and TEXT
- Language:
- Czech
- Description:
- Doc. MUDr. Jaroslav Kříž
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
267. Radiační zátěž pracovníků na Klinice nukleární medicíny a endokrinologie 2. LF UK a FN Motol v letech 2006-2011
- Creator:
- Hudzietzová, Jana, Prchalová, Dana, Sabol, Jozef, and Vlček, Petr
- Format:
- braille, text, and regular print
- Type:
- model:article, article, Text, práce podpořená grantem, and TEXT
- Subject:
- nemocnice fakultní--normy--pracovní síly, endokrinologie--normy--pracovní síly--přístrojové vybavení, nukleární lékařství--normy--pracovní síly--přístrojové vybavení, zdravotničtí pracovníci--normy, dávka záření, hygiena záření--metody--normy--přístrojové vybavení, radiační ochrana--metody--normy, referenční standardy, radiometrie--metody--přístrojové vybavení--využití, radiofarmaka--diagnostické užití--škodlivé účinky--terapeutické užití, radioizotopy jodu--škodlivé účinky--terapeutické užití, diagnostické zobrazování--metody--přístrojové vybavení--škodlivé účinky, statistika jako téma, retrospektivní studie, and lidé
- Language:
- Czech and English
- Description:
- Cíl. Záměrem práce bylo zhodnocení radiační zátěže pracovníků na Klinice nukleární medicíny a endokrinologie 2. LF UK a FN Motol (KNME) v letech 2006-2011 spolu s posouzením radiační ochrany pracoviště. Stanovení radiační zátěže na tomto pracovišti bylo vyhodnoceno na základě retrospektivní studie opírající se o příslušné údaje a výsledky monitorování. Metoda. Výsledky monitorování pracovníků KNME se vztahují k období 2006-2011. Na základě osobních a prstových dozimetrů byla stanovena průměrná kolektivní efektivní dávka a průměrná kolektivní ekvivalentní dávka na ruce od prstů až po předloktí personálu. Vyhodnocení bylo prováděno do března 2009 firmou Celostátní služba osobní dozimetrie Praha, od dubna 2009 monitoring realizovala firma VF a.s., a to v obou případech po měsíčních intervalech. Průměrná roční zpracovaná aktivita radiofarmak (radionuklidy 99mTc, 111In, 153Sm, 123I, 131I) se v tomto časovém období pohybovala v rozmezí 2,79-5900 GBq. Výsledky. Průměrná kolektivní efektivní dávka činila v jednotlivých letech 2006, 2007, 2008, 2009, 2010 a 2011 pro radiologické asistenty a sestry s atestací v oboru nukleární medicína na ambulanci hodnotu 1,14 mSv, 1,39 mSv, 1, 29 mSv, 0,99 mSv, 1,17 mSv a 1,11 mSv. Pro pracovníky radiofarmaceutické laboratoře na ambulanci byla průměrná kolektivní efektivní dávka za shodné časové období 0,29 mSv, 0,82 mSv, 0,52 mSv, 0,17 mSv, 0,36 mSv a 0, 50 mSv. Sestry na 2. lůžkové stanici obdržely průměrnou kolektivní efektivní dávku v daném časovém období, 0,73 mSv, 0,35 mSv, 0,22 mSv, 0,21 mSv a 0,39 mSv. V radiojódové laboratoři získali pracovníci průměrnou kolektivní efektivní dávku 3,00 mSv, 3,04 mSv, 3,33 mSv, 3,85 mSv, 2,04 mSv a 2,84 mSv. Průměrná kolektivní ekvivalentní dávka na ruce od prstů až po předloktí pracovníků (stanovována v témže časovém rozmezí 2006-2011) ve farmaceutické laboratoři dosahovala 23,00 mSv, 23,99 mSv, 23,19 mSv, 55,75 mSv, 167,81 mSv a 136,00 mSv. Pro radiologické asistenty na ambulanci a sestry s atestací nukleární medicína na ambulanci činila průměrná kolektivní ekvivalentní dávka na končetiny 4,35 mSv, 2,86 mSv, 0,88 mSv, 1,99 mSv, 3,48 mSv a 6,24 mSv. V radiojódové laboratoři byla vyhodnocena průměrná kolektivní ekvivalentní dávka ruce od prstů až po předloktí na 20,70 mSv, 18,21 mSv, 22,79 mSv, 44,76 mSv, 44,98 mSv a 54,03 mSv. Závěr. Hodnoty z osobních i prstových dozimetrů jsou pod dávkovými limity stanovenými dozorným orgánem, i když se ozáření pracovníků v jednotlivých letech mírně zvyšuje, což zřejmě souvisí s vyšším počtem a rozmanitostí prováděných diagnostických i léčebných úkonů. Na základě prezentovaných výsledků lze konstatovat, že radiační ochrana je na KNME zajištěna v souladu s požadavky Státního úřadu pro jadernou bezpečnost., Aim. The intention of the paper was the assessment of radiation burden at the Clinic of Nuclear Medicine and Endocrinology 2nd LF UK and FN Motol (KNME) during the period of 2006-2011 together with the examination of the level of radiation protection. The determination of radiation burden at this workplace was based on the retrospective study relying on relevant monitoring data and results. Method. Monitoring results of the personnel of the KNME are covering the period of 2006-2011. Using personal and finger dosimeters the average collective effective dose and average collective equivalent dose related to fingers up to forearms have been assessed. Until March 2009 the monitoring was carried out by the National Personal Dosimetry Service in Prague while as of April this monitoring was performed by VF Ltd. In both cases the monitoring interval was one month. The average activities of used radiopharmaceuticals (including 99mTc, 111In, 153Sm,123 I, 131I) was in the range of 2.79-5.900 GBq. Results. The average collective effective dose of radiological assistants and nurses certified in nuclear medicine in individual years, namely 2006, 2007, 2008, 2009, 2010 and 2012 was 1.14 mSv, 1.39 mSv, 1.29 mSv, 0.99 mSv, 1.17 mSv a 1.11 mSv, respectively. During the same period the personnel working in the radioiodine laboratory received average collective effective dose 0.29 mSv, 0.82 mSv, 0.52 mSv, 0.17 mSv, 0.36 mSv a 0.50 mSv. The average collective effective dose of nurses at the 2nd Ward was reported to be in those years 0.73 mSv, 0.35 mSv, 0.22 mSv, 0.21 mSv a 0.39 mSv. With respect to extremities, the average collective equivalent dose of the personnel in the radiopharmaceutical laboratory was thought out the above mentioned period was as follows 23.00 mSv, 23.99 mSv, 23.19 mSv, 55.75 mSv, 167.81 mSv a 136.00 mSv while the average collective equivalent dose received by radiological assistants on ambulance and certified on ambulance nurses amounted to 4.35 mSv, 2.86 mSv, 0.88 mSv, 1.99 mSv, 3.48 mSv a 6.24 mSv. The average collective equivalent dose to extremities of workers from the radioiodine laboratory during the period of 2006, 2007, 2008, 2009, 2010 a 2011 was 20.70 mSv, 18.21 mSv, 22.79 mSv, 44.76 mSv, 44.98 mSv a 54.03 mSv, respectively. Conclusion. The results of personal as well as finger dosimeters have been found to be below the relevant dose limits set by the Regulatory Authority although over some of the recent years the exposure of workers has slightly been increasing which apparently is related to the increased number and variety of diagnostic and therapeutic procedures. Taking into account the results presented, it can be concluded that radiation protection at the KNME is in full compliance with the requirements of the State Office for Nuclear Security., and Jana Hudzietzová, Dana Prchalová, Jozef Sabol, Petr Vlček
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
268. Radonový program v České republice pokračuje
- Creator:
- Lajčíková, Ariana
- Format:
- braille, text, and regular print
- Type:
- model:article, article, Text, přehledy, and TEXT
- Subject:
- lidé, vládní programy, nádory plic--etiologie--prevence a kontrola, radon--normy--škodlivé účinky, životní prostředí - monitorování--metody, radioaktivní látky znečišťující vzduch--normy--škodlivé účinky, znečištění vzduchu ve vnitřním prostředí--analýza--škodlivé účinky, vystavení vlivu životního prostředí--prevence a kontrola--škodlivé účinky, bydlení--normy, podpora zdraví - programy, and ochrana veřejného zdraví
- Language:
- Czech and English
- Description:
- Radonový program byl zahájen v 80. letech minulého století. Nyní probíhá jeho třetí dekáda. Autorka zastupuje v tomto programu ministerstvo zdravotnictví s hlavním úkolem šířit informace o riziku radonu a o možnostech ochrany zdraví. V článku je podána informace o aktuálních aktivitách., The Radon programme was launched in the 1980s and at present its 3rd decade is being realised. The autor is a representative of the Czech Ministry of Health with the main task to spread information about the risk of radon and about the possibilities of health protection. There is given information of topical interest about activities of the programme., Ariana Lajčíková, and Literatura
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
269. Redukce dávky ionizujícího záření na oční čočku u MDCT mozku s využitím výpočetního algoritmu iterativní rekonstrukce IRIS - první výsledky
- Creator:
- Jandura, Jiří, Žižka, Jan, Kvasnička, T., Grepl, Jan, and Klzo, Ludovít
- Format:
- braille, text, and regular print
- Type:
- model:article, article, Text, and TEXT
- Subject:
- multidetektorová počítačová tomografie--metody--přístrojové vybavení--využití, mozek--fyziologie--patofyziologie--patologie, obrazy - zpracování pomocí počítače--metody--využití, dávka záření, algoritmy, čočka oční--účinky záření, katarakta--diagnóza--etiologie--prevence a kontrola, vylepšení rentgenového snímku--metody--normy--přístrojové vybavení, radiační ochrana--metody--normy--přístrojové vybavení, řízení kvality, statistika jako téma, and lidé
- Language:
- Czech and English
- Description:
- Cíl. Srovnání efektivní dávky a orgánové dávky na oční čočku při vyšetřeních mozku multidetektorovým CT přístrojem (MDCT) s nastavenou automatickou modulací proudu, provedené výpočetním algoritmem iterativní rekonstrukce v obrazovém prostoru (IRIS) a algoritmem filtrované zpětné projekce (FBP). Metoda. Z celkem 80 neakutních MDCT mozku s nastavením automatické proudové modulace bylo 40 provedeno protokolem založeným na IRIS a 40 dalších protokolem s FBP. Všechna vyšetření byla realizována na MDCT přístroji SOMATOM Definition AS+ (Siemens Healthcare, Forchheim, Německo). Efektivní dávka byla vypočtena z CT dávkového indexu (CTDIvol) a dose length product (DLP) v prostředí softwaru ImPACT. Orgánové dávky na oční čočku byly vypočteny z hodnot mAs aplikovaných v úrovni oční čočky. Obrazová a diagnostická kvalita rekonstruovaných obrazů byla subjektivně hodnocena dvěma zkušenými atestovanými radiology v zaslepeném porovnání. Bylo také provedeno kvantitativní statistické hodnocení úrovně obrazového šumu. Výsledky. TJ IRIS byla průměrná efektivní dávka na oční čočku 1,04 ± 0, 21 mSv, u FBP 1,53 ± 0,29 mSv, což představuje snížení o přibližně 32 % ve prospěch IRIS. Průměrná orgánová dávka byla u IRIS 26,9 ± 1, 9 mGy a u FBP 40,2 ± 3,2 mGy, což představuje redukci o 33,1 %. Při subjektivním porovnání vjemu kvality obrazu nebyl zjištěn významný rozdíl (p = 0,21). V rámci kvantitativního hodnocení úrovně šumu bylo zaznamenáno malé, ale již statisticky významné zvýšení na obrazech rekonstruovaných algoritmem IRIS (p <0,01). Závěr. Použití výpočetního algoritmu IRIS při MDCT vyšetření mozku umožňuje redukovat efektivní a orgánovou dávku zachycenou oční čočkou až přibližně o jednu třetinu při diagnosticky nevýznamném rozdílu v kvalitě zobrazení v porovnání s algoritmem FBP., Aim. To compare effective and organ radiation dose to the eye lens in multidetector CT (MDCT) examinations of the brain, utilising either iterative reconstruction in image space (IRIS) or filtered back projection (FBP) algorithm. Method. Of 80 non-acute brain MDCT examinations, 40 were performed with IRIS reconstruction algorithm and other 40 with FBP algorithm. All examinations were performed on MDCT system SOMATOM Definition AS+ (Siemens Healthcare, Forchheim, Germany). Calculation of the effective dose was done by ImPACT software (Impact, London) using CT dose index (CTDIvol) and dose length product (DLP) values. Organ dose to the eye lens was calculated from mAs value applied to the slices containing the lens. Diagnostic image quality of reconstructed data was evaluated by two experienced radiologists in a blinded fashion. Results. For IRIS, the average effective dose to the eye lens was 1.04 ± 0.21 mSv and for FBP 1.53 ± 0.29 mSv, with a reduction of approximately of 32%. The average organ dose for IRIS was 26.9 ± 1.9 mGy and 40.2 ± 3.2 mGy for FBP, with a dose reduction of 33.1%. A comparison of image quality showed no statistically significant difference (p = 0.21). Quantitative analysis of image noise revealed slightly increased noise levels in the IRIS group, the difference was statistically significant (p < 0.01). Conclusion. IRIS reconstruction algorithm in cerebral MDCT examinations can reduce the effective and eye lens organ dose approximately by one third, without significant deterioration of image quality compared to FBP reconstruction algorithm FBP., and Jiří Jandura, Jan Žižka, Tomáš Kvasnička, Jan Grepl, Ludovít Klzo
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
270. Reforma zdravotnictví v Nizozemsku
- Creator:
- Hnilicová, Helena and Dobiášová, Karolína
- Format:
- 2-7, braille, electronic resource, remote, and elektronický zdroj
- Type:
- model:article, article, Text, statistics, práce podpořená grantem, and TEXT
- Subject:
- lidé, reforma zdravotní péče--ekonomika--etika--organizace a řízení, zdravotní politika, výdaje na zdravotnictví--statistika a číselné údaje, úhrada služeb Medicare, zdravotnické služby - dostupnost, politika zdravotní - programy, kvalita zdravotní péče, and zdravotní pojištění--organizace a řízení
- Language:
- Czech and English
- Description:
- Článek v širším historickém kontextu pojednává o dlouhodobě připravované reformě zdravotnictví v Nizozemsku, která byla završena v roce 2006. Analyzuje příčiny, které k reformě vedly a seznamuje s reformní strategií a jejím postupem. S odstupem několika let mapuje dopady reformy na dostupnost zdravotní péče, chování poskytovatelů i zdravotních pojišťoven a na pacienty. Nastiňuje ekonomické důsledky reformy a některé etické souvislosti., The article is focused on the long-planned health care reform in the Netherlands completed in 2006 in a broader historical context. The aim of the text is: firstly, to analyse the causes of the reform and secondly, to discuss reform strategy as well as its progress. After several years since reforms implementation there are mapping their impact on the access to health care and behaviour of health providers, insurance companies and patients. The article outlines the economic consequences of the reform and some ethical issues., Helena Hnilicová, Karolína Dobiášová, and Literatura
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public