Přehledové sdělení se věnuje diagnostickému zobrazení akutních aortálních syndromů s důrazem na multidetektorovou výpočetní tomografii a na její význam pro volbu léčby. Diskutovány jsou jednak techniky CT zobrazení včetně CT s EKG synchronizací a dále diagnostické nálezy u disekce aorty, intramurálního hematomu a penetrujícího vředu aorty. Literární data jsou konfrontována s vlastními zkušenostmi terciárního centra v populaci městského typu., Review payes attention to the importace of the diagnostic imaging in acute aortic syndromes concerning to the multidetector-row computed tomography and its impact on treatment decisions. The several CT techniques including CT with ECG synchronized acquisitions are discussed as well as the diagnostic findings of aortic dissection, intramural hematoma and penetrating aortic ulcer. Bibliographic data are faced with the own experience of the tertiary centre with urban population., Jiří Ferda, Petr Duras, Jan Baxa, František Šlauf, and Literatura
Cíl: Zhodnocení zkušeností s celotělovou magnetickou rezonancí na 3T systému. Metodika: Vyhodnotili jsme celkem 279 vyšetření provedených na přístroji 3T (SKYRA, Siemens, Německo) provedených během 36 měsíců a posoudili jejich indikace a zejména možnost zobrazení skeletu, ale i parenchymových orgánů při indikacích mnoho četného myelomu, lymfomů a ostatních nádorových onemocnění. Výsledky: Nejčastější indikací zůstává myelom (228), u celkem 35 vyšetření lymfomů jsme získali kvalitní diagnostické zobrazení, které umožňuje posoudit nejenom postižení lymfatických orgánů včetně sleziny, ale i kostní dřeně a plic. Difuzní zobrazení bylo shledáno dostatečné diagnostické kvality, avšak výrazně prodlužuje celý diagnostický protokol. Závěr: Celotělové vyšetření na 3T MRI je plně diagnosticky využitelné při hodnocení stagingu i restagingu mnohočetného myelomu, lymfomů i ostatních nádorů jako je karcinom prostaty., Aim: Evaluation of the experience with whole body magnetic resonance on 3T system. Method: 279 examinations performed on 3T system (SKYRA, Siemens, Erlangen, Germany) performed during 36 months were assessed according indications, possibility of imaging of the bone marrow, organs of the abdomen and lungs, when the indications are multiple myeloma, lymphoma or the other tumors. Results: The most frequent indication remains multiple myeloma (228), in 35 patients was performed lymphoma imaging with reached sufficient diagnostic imaging enabling assessment of the bone marrow, lymph nodes, lungs and parenchymatous organs. Diffusion weighted imaging on 3T is sufficient, but increases the imaging time significantly. Conclusion: Whole body imaging on 3T MRI is fully diagnostic in the evaluation of staging or restaging in multiple myeloma, lymhomas or the other tumors., Boris Kreuzberg, Jiří Ferda, Jan Kastner, and Literatura
Cíl. Posoudit stupeň korelace výsledků chemické analýzy urolitiázy pomocí výpočetní tomografie s duální energií záření (DECT) s laboratorní chemickou analýzou konkrementů a zhodnotit přínos metody DECT pro klinickou praxi. Metoda. Celkem 67 pacientů bylo vyšetřeno pomocí DECT s požadavkem na chemickou analýzu již známé či suspektní urolitiázy. K analýze chemického složení konkrementů pomocí DECT jsme využili simultánní expozici 140 kV a 80 kV. Získaná data byla analyzována pomocí programu Syngo Dual Energy Siemens v modulu Kidney Stones. U 30 pacientů byl následně proveden urologický výkon s extrakcí litiázy a jejím chemickým rozborem. V tomto souboru jsme pak korelovali výslednou chemickou skladbu urolitiázy získanou oběma metodami. Výsledky. V souboru 30 pacientů se podařilo prokázat u konkrementů velikosti nad 3 mm 100% senzitivitu a 100% specificitu DECT analýzy. V případě velmi drobné urolitiázy (tj. pod 3 mm) je přesnost detekce 100%, ale schopnost diferenciace na jednotlivé typy urolitiázy snížená na 97 %. Závěr. Metoda DECT analýzy urolitiázy vykazuje u konkrementů nad velikost 3 mm 100% shodu výsledků v porovnání s chemickou laboratorní analýzou močových konkrementů a má tedy velký přínos pro klinickou praxi, zejména v možnosti včasného zahájení vhodného terapeutického postupu., Aim. To assess the degree of correlation between the results of chemical analysis of urolithiasis using dual energy computed tomography (DECT) with laboratory chemical analysis of stone, and to evaluate the contribution of this method to clinical practice. Method. Total 67 patients underwent DECT in order to performe the chemical analysis of already known or suspected urolithiasis. To analyze the chemical composition of the stone using DECT, we used the simultaneous exposure to 140 kV and 80 kV. The obtained data were analyzed using software Syngo Siemens Dual Energy in program "Kidney Stones". The method of the analysis was based on a material decomposition algorithm. In 30 patients, the extraction ofthe stone followed and the chemical and crystalograpic analysis was made. The results of virtual chemical analysis and laboratory findings were compared. Results. In the stones greater than 3 mm, sensitivity and specificity reached 100% using DECT analysis. In the case of very small stone disease (ie. less than 3 mm), the detection reached 100% accuracy, but the ability to differentiate the correct type of stone disease decreased to 97 %. Conclusion. DECT analysis of urolithiasis shows the stones of size 3 mm with 100% match results in comparison with laboratory chemical analysis of urinary stones and therefore has great benefit for clinical practice, especially early in choosing the appropriate therapeutic procedure., Bednářová A, Ferda J, Kreuzberg B, Klečka J, Hora M., and Literatura 6
Cíl: Významem naší prospektivní studie je možnost významné redukce celkového objemu kontrastní látky při CTA DK díky optimalizaci akvizičního času na základě individuálních cirkulačních parametrů. Metoda: Celkem u 68 osob s ischemickou chorobou dolních končetin bylo prospektivně provedeno CT angiografické vyšetření břišní aorty a dolních končetin (CTA DK) s použitím kontrastní látky o objemu 40 ml (31 osob) a 50 ml (37 osob) a vysokou rychlostí aplikace (6 ml/s). Akviziční čas byl individuálně vypočten na základě aorto-popliteálního (Ao-P) tranzitního času získaného stanovením denzitní bolusové křivky na dvou úrovních (aorta/popliteální tepna) po jednorázovém podání 10 ml kontrastní látky (tzv. dvojitý testovací bolus). Kvalita vyšetření vyšetření byla hodnocena subjektivním (skóre 1-3) a objektivním měřením denzity v pěti úrovních. Vyšetření byla označena jako nediagnostická, pokud byla alespoň jedna oblast při subjektivním hodnocení ohodnocena skórem 3. Ve statistickém hodnocení byla porovnána dosažená kvalita s hodnotami akvizičního času a zpoždění. Výsledky: Prokázali jsme statisticky významnou korelaci akvizičního času (21-43) a subjektivního (p = 0,0015) a objektivního (p = 0,0117) hodnocení kvality. Také v případě Ao-P tranzitního času byla prokázána statistická korelace s hodnocením kvality (0,0013, resp. 0,0191). Signifikantně vyšší akviziční čas byl použit u vyšetření s celkově subjektivně nediagnostickou kvalitou (p = 0, 073) a ve všech případech byl vyšší než 31 s. Naopak všechna vyšetření s akvizičními časy pod 30 s byla plně diagnostická. Při podání 50 ml kontrastní látky bylo dosaženo významně vyšší denzity v jednotlivých sledovaných úrovních (p = 0,076), hodnoty akvizičního času a Ao-P tranzitního času se významně mezi skupinami s různým množstvím kontrastní látky nelišily. Závěr: Naše práce prokázala možnost významné redukce objemu kontrastní látky při CTA DK za pomoci optimalizace akvizičního času na základě Ao-P tranzitního času, který byl získán po jednorázové aplikaci 10 ml kontrastní látky (dvojitý test bolus). Byla prokázána statisticky významná korelace akvizičního času a Ao-P tranzitního času na kvalitě provedených vyšetření., Aim: The goal of the prospective study is to determine feasibility of peripheral CT angiography (CTA) with adaptive scan time using low volume of contrast agent. Methods: We performed CTA in extent of abdominal aorta and lower limbs on dual-source CT in two groups of patients with different volumes of contrast agent (400 mgl/l). Volumes of 40ml (31 patients) and 50 ml (21 patients) with 6ml/s injection were used for examinations. Individual scan time was calculated from peak transit time established from double test bolus (single administration of 10 ml) measurements (proximal abdominal aorta and popliteal arteries). We analyzed subjective quality of CTA (1-3) and objective quality (intraluminal density and CNR) in 5 different levels. Examinations with subjective quality 3 (non-diagnostic) in one level were considered as overall non-diagnostic. Results: We found significant correlation between scan time (21-43 s) and subjective (p = 0.0015) and objective quality (p = 0.0117) in both groups. Significantly higher (p = 0.029) scan time was used in examinations with overall non-diagnostic quality (6 in 40 ml group and 3 in 50 ml group). The scan times in non-diagnostic examinations were completely over 31s (31.6-42.4) and all examinations with scan time below 30 s were with excellent quality. Significantly better objective quality was reached in 50 ml group (p = 0.076). Time parameters were not significantly different in both groups. Conclusion: Our results have proved feasibility of peripheral CTA with adaptive scan time and low volume of contrast agent. There is significant correlation of used scan time and AoP peak transit time with quality with probability of determination of suitable group of patients., Jan Baxa, Jiří Ferda, Tomáš Vendiš, Jiří Moláček, Vladislav Třeška, and Literatura
Cíl. Práce je zaměřena na možnosti provedení CT angiografie břišní aorty a dolních končetin na nové generaci dvouzdrojového CT přístroje využívající skenování s vysokým pitch faktorem a ohledem na redukci radiační zátěže a množství podávané kontrastní látky. Metoda. V rámci prospektivní studie bylo vyšetřeno 29 osob s klinickými známkami či již známým postižením tepen dolních končetin. Vyšetření byla provedena na přístroji Somatom Definition FLASH (Siemens, Německo), použita kolimace 128 x 0,6 mm, rychlá rotace rentgenky (0,28 s/otáčku) a vyšším fázovým posunem (pitch faktor 1,55). Kontrastní látka v množství 60-70 ml byla aplikována rychlostí 5 ml/s, načasování akvizice bylo provedeno na základě monitorace testovacího bolusu (10 ml) v popliteálních tepnách. Hodnocení kvality zobrazení bylo provedeno na základě vizuálního posouzení a stanovení denzity v jednotlivých částech tepenného systému. Výsledky. Ve všech případech bylo dosaženo vysoké kvality zobrazení aorty, pánevních, femorálních i popliteálních tepen na základě vizuálního hodnocení i stanovení denzity (aorta - 456,3 HU, třísla - 507,3 HU, podkolenní - 554,3). V případě distální části bérců a nohy došlo u tří osob k suboptimální náplni vlivem rychlejší akvizice vůči postupu bolusu kontrastní látky. Pouze v jednom případě byla distální oblast bérců nehodnotitelná. Průměrná úroveň denzity v úrovni kotníků byla 367,7 HU. Průměrná radiační dávka byla nízká -CTDIvol 2,40, efektivní dávka 1,79 mSv. Závěr. První výsledky naší prospektivní studie prokázaly možnost provedení CT angiografie dolních končetiny pomocí "high-pitch" módu. Přes velmi nízkou hodnotu radiační dávky i aplikovaného množství kontrastní látky bylo dosaženo vysoké diagnostické kvality v oblasti aorty, pánve stehen a proximálních částí bérců. Tento způsob vyšetření je zvlášť vhodný pro osoby s vysokým rizikem kontrastní nefropatie, eventuálně pro mladé osoby v produktivním věku., Aim. Our work was focused on the feasibility of CT angiography of abdominal aorta and lower limbs using new generation of dual-source CT with a high pitch factor, concerning on the reduction of radiation exposure and the amount of administered contrast agent. Methods. In the prospective study were examined 29 patients with clinical signs, or known disability of lower limbs arteries. The examinations were performed on the Somatom Definition Flash (Siemens, Germany) using collimation 128 x 0.6 mm, high tube rotation speed (0.28 s/rotation) and a higher pitch factor of 1.55).Amount of contrast agent (60 to 70 ml) was applied at 5 ml/s, the timing of acquisition was based on results of the test bolus monitoring (10 ml) in the popliteal arteries. Evaluation of image quality was based on visual assessment and determination of density in different parts of the arterial system. Results. In all cases were achieved a high display quality of the aorta, pelvic, femoral and popliteal arteries by visual assessment and also determination of luminal density (aorta - 456.3 HU, groin - 507.3 HU, knee - 554.3). In the region of the distal leg and ankle occurred in 3 people in suboptimal quality due to overrun of bolus. Only in one case, the distal region leg was uninterpretable. The average level density at ankle level was 367.7 HU. The average radiation exposure was low - CTDIvol 2.40,1.79 mSv effective dose. Conclusion. The preliminary results of our prospective study showed the possibility of performing CT angiography of the lower limbs in "high-pitch" mode. Despite the very low radiation dose and the amount of applied contrast agent was achieved a high diagnostic quality of the aorta, pelvic, femoral, popliteal and proximal crural arteries. This test method should be especially recommended for people at high risk of contrast nephropathy and for young people., Jan Baxa, Jiří Ferda, Petr Duras, Jiří Moláček, Petr Havránek, Hynek Mírka, and Literatura 18
Cíl. Posoudit vliv iterativní rekonstrukce dat na efektivní dávky vyšetření CT s duální energií záření (DECT). Metoda. Byla zhodnocena efektivní dávka u celkem jedenácti skupin po 40 vyšetřeních provedených na dvouzdrojovém přístroji první a druhé generace za použití režimu jednozdrojového jednoenergetického a DECT s použitím iterativní rekonstrukce technikou sinogram affirmed iterative reconstruction (SAFIRE) v oblasti hrudníku a břicha včetně protokolů využívajících dvoufázové akvizice dat v režimu DECT. Výsledky. Bylo prokázáno pomocí t-testu pro nezávislé výběry, že mezi vyšetřeními na přístroji druhé generace dvouzdrojového CT s použitím iterativního algoritmu SAFIRE není statisticky významný rozdíl v dávce mezi režimem jednozdrojovým jedno-energetickým režimem DECT (p = 0,0299; 0,9337; 0, 8207), naopak významný rozdíl je mezi protokoly DECT bez iterativní rekonstrukce a s ní (p < 0,0001 u všech porovnání). Závěr. Iterativní rekonstrukce umožňuje významně snížit efektivní dávku i protokolech DECT a zachovat dávkovou neutralitu ve srovnání s vyšetřeními na jednozdrojových systémech., Aim. To evaluate the influence of the iterative reconstruction on the effective dose obtained from dual-energy CT (DECT). Method. The effective dose was calculated within the 11 groups per 40 examinations performed using first and second generation of dual-source systems. Examinations were obtained in single-source single-energy and dual-source dual-energy regimens in thoracic or abdominal regions including the protocols containing iterative data reconstruction using algorithm sonogram affirmed reconstruction (SAFIRE). Results. Using the t-test for independent data samples was confirmed, that the effective dose obtained with DECT regimen does not differ from those obtained in single-source-single-energy regimen, even if both using SAFÍRE algorithm (p = 0.0299; 0.9337; 0.8207), but on the other side the significant diference occured between DECT with and without iterative reconstruction (p < 0.0001 in all). Conclusion. The iterative reconstruction enables the significant reduction of the effective dose in DECT to the doses equivalent to single-source sytems., and Jiří Ferda, Jan Baxa, Hynek Mírka, Boris Kreuzberg
Nádory měkkých tkání jsou rozsáhlou a značně heterogenní skupinou onemocnění vyžadující multimodalitní diagnostický přístup. Magnetická rezonance se stala díky vysoké senzitivitě a kontrastnímu rozlišení nejefektivnější metodou při jejich detekci a lokálním stagingu. Její možnosti při stanovení histologického typu nádoru a často i při rozhodnutí, zda je leze benigní či maligní jsou značně omezené. Z tohoto důvodu musí být až na výjimky kombinována s histologickým vyšetřením, které je rovněž nezbytné pro kompletní staging. Článek se zabývá technikou vyšetřování nádorů měkkých tkání pomocí magnetické rezonance a využitím metody při stagingu a diferenciální diagnóze. Krátce jsou zmíněny i možnosti dalších zobrazovacích modalit., Soft tissue tumors are large and heterogenous group of diseases requiring multimodality diagnostic approach. Magnetic resonance is, thanks to its high sensitivity and contrast resolution, the most effective method for their detection and local staging. Its possibilities in determining the histological type of tumor and in the decision whether the lesion is benign or malignant are quite limited. For this reason it MRI must be, with few exceptions, combined with histological examination, which is also necessary for complete staging. This article deals with MRI examination technique and the use of this method for staging and differential diagnosis. The possibilities of other imaging modalities are also briefly mentioned., Hynek Mírka, Jiří Ferda, Jan Kastner, Boris Kreuzberg, Tomáš Pavelka, Michal Michal, and Literatura
Autoři prezentují kazuistiku 3leté holčičky, u které byla pomocí zobrazovacích metod (USG a CT) prokázána přítomnost střevního parazita (škrkavka dětská, Ascaris lumbricoides) v tenkém střevě komplikovaná vícečetnou intermitentní intususcepcí., The authors present a case report of a 3-year-old girl, with proving presence of intestinal parasites (roundworm, Ascaris lumbricoides) in the small intestine complicated brains of intermittent intussusception. Ultrasound and CT were major diagnostic tools in this case., Jan Baxa, Jana Cibulková, Renata Vondráková, Boris Kreuzberg, Jiří Ferda, and Literatura
Cíl: Prospektivní sledování pacientů po prodělané akutní myokarditidě s cílem posoudit přínos a bezpečnosti pravidelného sledování pacientů pomocí magnetické rezonance (MR), laboratorních hodnot kardiospecifických enzymů a bicyklové ergometrie s ohledem na možné zkrácení doporučovaného přísného klidového režimu. Metodika: U 21 pacientů s diagnostikovanou akutní myokarditidou (včetně přítomnosti pozdního sycení - LGE při vstupní MR) byla v intervalu 1 a 6 měsíců provedena kontrolní MR, stanovení hladiny hypersenzitivního troponinu I (hs-Tn) a bicyklová ergometrie. Obrazová analýza byla zaměřena na vývoj rozsahu a intenzity LGE lézí v MR, výsledky byly porovnány s vývojem hs-Tn a výsledku bicyklové ergometrie po 1 měsíci. Výsledky: Předběžné výsledky studie prokázaly, že u všech pacientů byla prokázána regrese rozsahu i intenzity LGE při kontrolních vyšetřeních a zároveň nebyl prokázán rozvoj systolické dysfunkce levé komory srdeční u žádného pacienta. Tento vývoj korespondoval s vývojem průměrné hodnoty hs-Tn (z 9214,2 µg/1 na 25,4 µg/1). Při bicyklové ergometru nebyly prokázány závažné arytmie a všichni pacienti prokázali dobrou toleranci fyzické zátěže (minimálně 150 W). Závěr: Předběžné výsledky naší studie ukazují, že kombinace magnetické rezonance, hodnoty hs-Tn a bicyklové ergometrie je bezpečná a přínosná pro sledování pacientů po prodělané akutní myokarditidě. Důkladná analýza provedených výše uvedených vyšetření v delších intervalech je nezbytná pro možnou stratifikaci rizika u pacientů i s ohledem na délku doporučeného klidového režimu., Aim: Prospective study of patients following an acute myocarditis in order to assess the benefits and safety of regular monitoring using MRI, laboratory values of cardiac enzymes and exercise ECG. Methods: 21 patients with acute myocarditis (diagnosis including the presence of late gadolinium enhancement - LGE at acute MR) underwent in 1 and 6 months interval a follow-up MRI, level of hypersensitive tro-ponin I (hs-Tn) and the exercise ECG. Image analysis was focused on the development of LGE extent and intensity, results were compared with the development of hs-Tn and exercise ECG in 1 month follow-up. Results: Preliminary results of the study prove regression of the extent and intensity of LGE in all patients and normal left ventricular systolic function in all patients in 1 and 6 months follow-up. This trend corresponds with the development of the average value of hs-Tn (from 9214.2 µg/1 to 25.4 µg/1). During exercise ECG severe arrhythmia was not identified and all patients showed good tolerance of physical burden (at least 150 W). Conclusion: Preliminary results of our study indicate that the combination of MR, the value of hs-Tn and exercise ECG is safe and beneficial for follow-up of patients after acute myocarditis. A thorough analysis at longer intervals is necessary for possible risk stratification of patients with regard to the duration of recommended rest interval duration., Jakub Šedivý, Jan Baxa, Milan Hromádka, Táňa Matoušková, Richard Rokyta, Jiří Ferda, and Literatura
Cíl: Charakterizovat zobrazovací vlastnosti lymfomů mozku s ohledem na klinický význam tohoto méně častého nádorového onemocnění mozku. Metodika: Retrospektivní analýza výsledků CT a MR zobrazovacích vyšetření u pacientů s ložiskovým lymfomovým postižením mozku diagnostikovaným v naší fakultní nemocnici v letech 2001-2013. Výsledky: Hodnoceno bylo 30 pacientů, medián věku 60 (24-82) let. CT vyšetření provedeno u 25/30 a dostupné k revizi bylo u 20 z nich, MR provedeno u 24/30 a dostupné k revizi bylo u 21 pacientů. Primární a izolované postižení mozku lymfomem (histologicky non-hodgkinský difuzní velkobuněčný lymfom) bylo u 22/30 (73 %), u ostatních se jednalo o non-hodgkinský lymfom se systémovým postižením (4/30) nebo recidivu izolovaně v mozku (4/30). Medián počtu ložisek byl jeden (1-8) a v jednom případě šlo o diseminované postižení s desítky ložisek. Medián velikosti ložisek 28 x 30 x 29 (11 x 16 x 20 až 85 x 76 x 65) mm. Zásadní vlastností lymfomů mozku při MR vyšetření byl nález ložiskového procesu s výrazným, převážně homogenním kontrastním sycením, restrikcí difúze a rozsáhlým kolaterálním edémem s malým expanzivním chováním. Pouze u 2/16 pacientů s provedenou lumbální punkcí byla zastižena přítomnost NHL v likvoru. Závěr: Při specifikaci ložiskového postižení mozku pomocí MR je nutné vždy myslet i na možnost postižení lymfomem a zvolit protokol vyšetření s kontrastní látkou a difuzně váženými sekvencemi. Zobrazovací metody a biopsie by měla být provedena před zahájením kortikoterapie, která modifikuje obraz postižení., Aim: To revise and verify imaging methods characteristics of clinically significant and relatively rare brain lymphomas. Methods: Retrospective analysis of CT and MR imaging methods results in patients with brain lymphoma diagnosed in 2001-2013 at our university hospital. Results: 30 patients with median age of 60 (24-82) years were analysed. CT were performed in 25/30, MR in 24/30 patients, and 20 CT and 21 MR were available for retrospective revision. The primary and isolated brain lymphoma (histologically non-hodgkin Difuse Large B-cell Lymphoma) was defined in 22/30 (73%) patients, in the others the systemic Non-Hodgkin lymphoma (4/30) or isolated relapse (4/30) were present. Median number of NHL lesions was one (1-8), in one case there were tens of lesions present. Median diameter of the lesions was 28 x 30 x 29 (11 x 16 x 20 to 85 x 76 x 65) mm. The fundamental finding in brain lymphoma MR imaging was lesion with marked contrast enhancement, predominantly homogenous, diffusion restriction and large collateral oedema with minimal expantion. Only in 2 out of 16 patients with lumbar puncture, lymphoma presence in fluid was detected. Conclusion: When specifying brain focal lesions on MR, it is necessary to consider lymphoma etiology and to elect imaging protocols with contrast agents and diffusion weighted sequence. Imaging methods and biopsy should be performed prior to start of corticosteroid therapy, as this modifies the characteristics of the lesions., Radek Tupý, Jiří Ferda, Jan Kastner, Hynek Mírka, Samuel Vokurka, and Literatura