« Previous |
21 - 29 of 29
|
Next »
Number of results to display per page
Search Results
22. Prof. MUDr. Leo Steinhart, DrSc. - devadesátiletý
- Creator:
- Krajina, Antonín
- Format:
- print, text, and regular print
- Type:
- model:article, article, Text, biography, biografie, and TEXT
- Subject:
- Steinhart, Leo , 1924- and radiologie
- Language:
- Czech
- Description:
- Antonín Krajina
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
23. Radiologicky zaváděné centrální žilní porty určené k vysokorychlostnímu podání kontrastní látky, tzv. power nebo CT porty - naše první zkušenosti
- Creator:
- Hájek, Jan, Chovanec, Vendelín, Krajina, Antonín, Renc, Ondřej, Raupach, Jan, Slováček, Ladislav, Merglová, Ilona, Hanousková, Petra, Pilař, Martin, Kašová, Silvie, and Lerchová, Jana
- Format:
- braille, text, and regular print
- Type:
- model:article, article, Text, and TEXT
- Subject:
- lékařská onkologie--metody--trendy, zaváděcí katetry--škodlivé účinky--trendy--využití, kontrastní látky--aplikace a dávkování--diagnostické užití, intervenční ultrasonografie--metody--přístrojové vybavení--trendy, intervenční radiografie--metody--využití, tomografie rentgenová počítačová--metody--trendy--využití, multidetektorová počítačová tomografie--metody--trendy--využití, venae jugulares, intravenózní infúze--metody--trendy--využití, výsledky a postupy - zhodnocení (zdravotní péče), statistika jako téma, průzkumy a dotazníky, prospektivní studie, lidé, intravenózní přístup, port, power portkatétr, procedurální komplikace, and pozdní komplikace
- Language:
- Czech and English
- Description:
- Cíl. Nové typy portkatétrů umožňují podávání kontrastních látek velkými rychlostmi až 5 ml/s. Cílem práce bylo zhodnocení přínosu vysokotlakých portkatétrů, tzv. power portů pro pacienty a jejich využívání v klinické praxi. Materiál a metodika. V období 7 měsíců bylo u 54 nemocných na dvou pracovištích implantováno 54 power port systémů umožňujících vysokorychlostní podání kontrastní látky. Tito pacienti byli prospektivně sledováni. Jednalo se o skupinu 33 žen a 21 mužů průměrného věku 52,6 let (22-74 let). Zavádění probíhalo na pracovišti intervenční radiologie s použitím ultrazvukové a skiaskopické navigace. Po výkonu bylo dotazníkovou metodou a telefonickým pohovorem zjišťováno využití portu při podání jódové kontrastní látky u CT vyšetření. Výsledky. Primární technická úspěšnost implantace v našem souboru byla 100%. Žádná významná periprocedurální komplikace nebyla zaznamenána. Portkatétr byl extrahován u tří pacientů (5,6 %), jednou pro centrální trombózu a dvakrát pro infekční komplikaci systému. Jeden pacient během sledování zemřel a dalších pět pacientů bylo ztraceno ze sledování. Průměrná doba sledování pacientů byla 138 dní (30-212 dní). V průběhu sledování bylo provedeno 18 kontrastních CT vyšetření u 17 pacientů (34,7 %). Portkatétr byl užit u devíti pacientů k provedení 9 CT vyšetření (52,9%, resp. 50%) a periferní žíla byla kanylovaná u osmi pacientů pro 9 CT vyšetření (47,1 %, resp. 50 %). Během CT vyšetření s užitím portkatétrů nebyla zaznamenána žádná procedurální komplikace. Důvodem, proč nebyla kontrastní látka podána přes portkatétr, byla nezkušenost personálu CT pracovišť s napichováním komůrky portkatétrů. Závěr. Technika radiologicky asistované implantace power portů a konvenčních portů se neliší. Vysokorychlostní podávání kontrastní látky přes portkatétry proběhlo bez komplikací. Procento portkatétrů použitých k podání kontrastní látky je srovnatelné s literárními údaji. Proškolení zdravotnického personálu a informovanost zejména na CT pracovištích by mělo vést k vyššímu využití power portkatétrů., Aim. A new type of portcatheter allows high pressure aplication of contrast agent. We report prospective evaluation of central venous power portcatheters including their clinical benefit. Material and method. We have implat-ed 326 portcatheters during 7 months period (from March to September 2011). This group included 54 patients with power portcatheters (33 women and 21 men with mean age 52.6 years). Procedures were performed in local anesthesia under sonographic and fluoroscopic guidance. Results. Primary technical success was 100% with none procedural complication. Portcatheter had to be removed in 3 patients (5.6%) due to port system infection in two patients and central vein thrombosis in one. One patient died and 5 patients were lost from follow-up. Mean follow-up was 138 days (range 30-212 days). During follow-up, 18 contrast enhaced CT scans were performed in 17 patients (34.7%). Power portcatheter was used in 9 patients for 9 CT scans (52.9%, respectively 50%) and peripheral vein in 8 patients for 9 contrast CT scans (47.1%, respectively 50%). During contrast CT examination, none complication related to the implanted device occurred. Conclusion. The procedure of power portcatheter implantation is the same as for conventional portcatheters. High pressure contrast media injection through the device was feasibile and without complication. Radiological staff education and awareness seems to be important for more frequent power portcatheter utilization for contrast enhaced CT examination., Jan Hájek, Vendelín Chovanec, Antonín Krajina, Ondřej Renc , Jan Raupach, Ladislav Slováček, Ilona Merglová, Petra Hanousková, Martin Pilař, Silvie Kašová, Jana Lerchová, and Literatura 15
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
24. Role neuroradiologa v léčbě ischemických cévních mozkových příhod
- Creator:
- Krajina, Antonín and Krajíčková, Dagmar
- Format:
- print, text, and regular print
- Type:
- model:article, article, Text, randomizované kontrolované studie, and TEXT
- Subject:
- cévní mozková příhoda--chirurgie--radiografie, trombektomie--metody--přístrojové vybavení, trombolýza mechanická--metody--přístrojové vybavení, endovaskulární výkony--metody--přístrojové vybavení, stenty, mozková angiografie--metody--přístrojové vybavení, časové faktory, věkové faktory, lidé, and prospektivní studie
- Language:
- Czech and English
- Description:
- Rekanalizace uzávěru velkých mozkových tepen je základem předpokladu příznivého výsledku léčby akutní ischemické cévní mozkové příhody (CMP). Intravenózní trombolýza provedená rekombinantním tkáňovým aktivátorem plazminogenu (rtPA) byla zkoumána v několika kontrolovaných randomizovaných studiích a ukázala se být bezpečnou a efektivní léčbou. Účinnost této léčby je střední. Mechanická trombektomie představuje další krok v léčbě akutní CMP. Několik prospektivních randomizovaných studií prokázalo pozitivní výsledky endovaskulární léčby u nemocných s proximálním arteriálním uzávěrem. Bylo nutné vyloučit nemocné s velkou zónou infarktu pomocí rychlých, efektivních zobrazovacích metod. Zásadní je logistika pacientů a dosažení rychlé rekanalizace s vysokou úspěšností. Použití stent retrieverů se prokázalo být vysoce efektivní jak technicky tak klinicky., Recanalization after large vessel occlusion is proven to be a crucial predictor for favorable outcome in acute ischemic stroke. Intravenous thrombolysis with recombinant tissue plazminogen activator (rtPA) has been investigated in several randomized controlled studies and is shown to be a safe and effective treatment. However, efficacy of this therapy is moderate. Mechanical thrombectomy represents further step in the treatment of acute stroke. Several prospective randomized studies proved benefit of the endovascular treatment based on proof of proximal artery occlusion, rapid and effective imaging methods to exclude patients with a large infarct core and efficient workflow to achieve fast recanalization and high recanalization rate. Using the stent-retriever technique proved to be highly technically and clinically effective., Antonín Krajina, Dagmar Krajíčková, and Literatura
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
25. Snížení radiační zátěže při angiografických výkonech s využitím systému ClarityIQ
- Creator:
- Rek, Michal, Grepl, Jakub, Krajina, Antonín, Čermáková, Eva, Malý, Radovan, Chovanec, Vendelín, Renc, Ondřej, and Raupach, Jan
- Format:
- braille, text, and regular print
- Type:
- model:article, article, Text, srovnávací studie, and TEXT
- Subject:
- rentgendiagnostika--přístrojové vybavení--trendy, angiografie--přístrojové vybavení--škodlivé účinky, dávka záření, záření ionizující, obsah radioaktivních látek v organizmu, obrazy - zpracování pomocí počítače, radiační ochrana--statistika a číselné údaje, vztah dávky záření a odpovědi, mužské pohlaví, ženské pohlaví, lidé, efektivní dávka, intervenční radiologie, and skiaskopie
- Language:
- Czech and English
- Description:
- Cíl: Vytvoření kvalitního digitálního obrazu systémem ClarityIQ na angiografickém přístroji AlluraClarity Xper FD 20/20 (Philips Medical System, Best, Holandsko) je spojeno s nižší radiační zátěží pacienta než u předchozí generace přístrojů. Cílem práce bylo srovnání efektivních dávek ionizujícího záření na dvou angiografických přístrojích Allura Xper FD 20 (Philips Medical System, Best, Holandsko) a Philips Allura Clarity Xper FD 20/20 (Philips Medical System, Best, Holandsko). Metodika: V retrospektivní studii jsme analyzovali konsekutivně vybraných 100 angio-intervenčních vyšetření provedených u 100 nemocných v časovém období od 1. 7. 2012 do 1. 7. 2013. Na angiografickém kompletu Philips Allura Clarity Xper FD 20/20 (Philips Medical System, Best, Holandsko) s technologii ClarityIQ byla konsekutivně vybrána vyšetření 50 nemocných (34 mužů, 16 žen průměrného věku 64 let, průměrné hmotnosti 79 kg a průměrné výšce 170 cm). Na přístroji Allura Xper FD 20 (Philips Medical System, Best, Holandsko), který nepracuje se systémem ClarityIQ, bylo konsekutivně vybráno 50 pacientů (30 mužů, 20 žen, průměrného věku 64 let, průměrné hmotnosti 78 kg a průměrné výšce 170 cm). Dané skupiny byly rozděleny podle druhu intervenčního výkonu na podskupiny čítající 10 provedených intervenčních vyšetření na každém z přístrojů: vytvoření transjugulárních intrahepatálních portosystémových spojek (TIPS), zavedení břišních stentgraftů u aneuryzmatu břišní aorty, provedené neurointervenční ošetření u pacientů po prodělaném subarachnoideálním krvácení z aneuryzmatu na mozkové cévě (SAK), provedené neurointervenční ošetření u pacientů s prodělanou cévní mozkovou příhodou (CMP), provedené neurointervenční ošetření zavedením stentu u pacientů s karotickou stenózou (CAS). U vytvořených podskupin jsme výpočtem stanovili hodnoty efektivních dávek. Statistická významnost snížení efektivních dávek pacientů vyšetřených na přístroji vybaveném systémem ClarityIQ byla prokázána testem ve statistickém programu NCSS 2007. Výsledky: Významné snížení radiační zátěže použitím systému ClarityIQ bylo prokázáno výrazným poklesem efektivních dávek. Snížení efektivní dávky se pohybovalo od 50 % do 70 % a bylo statisticky významné. Závěr: Systém ClarityIQ významně snižuje radiační zátěž pacienta spojenou s výkony v oblasti intervenční radiologie, a proto by měla být přístrojům s podobnými systémy dána přednost., Aim: Creation of a high-quality digital image system ClarityIQ on angiography equipment AlluraClarity Xper FD 20/20 (Philips Medical System, Best, The Netherlands) is associated with lower patient radiation burden than the previous generation of equipments. The aim of the study was to compare the effective doses of ionizing radiation on two angiographic intervention equipments Allura Xper FD 20 (Philips Medical System, Best, The Netherlands) and Philips Allura Xper FD Clarity 20/20 (Philips Medical System, Best, The Netherlands). Methods: In this retrospective study we analyzed 100 interventional examinations consecutively performed in 100 patients from 1st July 2012, until 1st July 2013. Fifty patients (34 males, 16 females, mean age 64 years, average weight 79 kg and average height 170 cm) were examined using the angiography set Philips AlluraClarity FD 20/20 employing the ClarityIQ technology. Fifty patients (30 males, 20 females, mean age 64 years, average weight 78 kg and average height 170 cm) were examined using the Allura Xper FD 20 set that does not work with the ClaritylQ system. The groups were divided according to the type of intervention on the performance of subgroups comprising 10 interventional procedures on each of the machine: the creation of transjugular intrahepatic portosystemic shunts (TIPS), the implantation of abdominal stentgrafts for abdominal aortic aneurysm, neurointerventional procedures in patients after subarachnoideal hemorrhage from a cerebral aneurysm (SAH), neurointerventional treatment of the patients with ischemic stroke, patients with carotid artery stenting (CAS). The generated subgroups are determined by calculating the values of effective doses. The statistical significance of the reduction in effective doses of patients examined on the device that is equipped with ClaritylQ was demonstrated by tests of statistical program NCSS 2007. Results: Significant reduction of radiation burden to patients has been shown by significant decrease of effective doses in the ClarityIQ system. The effective dose decrease ranged from 50% to 70% and was proved to be statistically significant. Conclusion: The ClarityIQ significantly reduces radiation dose to the patient associated with the performance of interventional radiology procedures, and therefore equipments with similar systems should be preferred., Michal Rek, Jakub Grepl, Antonín Krajina, Eva Čermáková, Radovan Malý, Vendelín Chovanec, Ondřej Renc, Jan Raupach, and Literatura
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
26. Spinální arteriovenózní malformace – dvě kazuistiky
- Creator:
- Andrašinová, T., Mičánková Adamová, Blanka, Krajina, Antonín, and Andrašina, Tomáš
- Format:
- print, text, and regular print
- Type:
- model:article, article, Text, kazuistiky, and TEXT
- Subject:
- arteriovenózní malformace--diagnóza--klasifikace--patofyziologie--terapie, páteřní kanál--krevní zásobení--patofyziologie, cévy--anatomie a histologie, diagnostické zobrazování, neurologické vyšetření, bolesti zad--diagnóza--etiologie, magnetická rezonanční tomografie, příznaky a symptomy, embolizace terapeutická--využití, endovaskulární výkony, angiografie, krvácení--etiologie, paréza--etiologie, výsledek terapie, diferenciální diagnóza, aneurysma, anestetika lokální--terapeutické užití, tomografie rentgenová počítačová, popis nemoci, dospělí, ženské pohlaví, lidé, and mužské pohlaví
- Language:
- Czech and English
- Description:
- Spinální arteriovenózní malformace jsou skupina vzácných onemocnění, jejichž klinické projevy mohou být velmi rozmanité. Optimální léčebný postup je nutno vždy volit individuálně a pacienty směřovat do specializovaných center. Cílem sdělení je uvést přehlednou klasifikaci SAVM, jejich diferenciální diagnostiku a terapii a dále prezentovat dvě kazuistiky. První kazuistika se zmiňuje o případu 27letého muže, u kterého se rozvinuly silné bolesti bederní páteře s dominující meningeální symptomatikou v klinickém obraze. Na MR hrudního úseku páteře (Th11/12) byla nalezena AVM zásobovaná hypertrofickou radikulopiální tepnou. Na specializovaném pracovišti byla provedena úspěšná embolizace AV zkratu. Druhá kazuistika uvádí případ 41leté ženy, které vznikla při lyžování náhlá prudká bolest za krkem. V neurologickém obraze došlo k rozvoji inkompletní léze míšní s kvadruparézou s levostrannou akcentací do těžkého stupně s hranicí čití ve výši C1. Na provedeném MR a MRAG krční míchy a následně na DSA vertebrálních tepen byla detekována AVM zásobovaná levou arteria spinalis posterior. Terapeuticky byla indikována elektivní endovaskulární embolizace a pacientka byla ošetřena na specializovaném pracovišti ve Francii., Spinal arteriovenous malformations are a group of rare diseases with highly diverse clinical manifestations. The optimal therapeutic practice should always be selected individually and patients should be sent to specialized centres. The objective of this paper is to provide a structured classification of spinal AVMs, their differential diagnosis and therapy, and to present two case reports. The first report is concerned with a case of a 27-year-old man who developed severe pain in the lumbar spine with predominantly meningeal symptomatology. An AVM fed by a hypertrophic radiculopial artery was found on the thoracic spine (Th11/12) MR. A specialized centre performed successful embolization of an arteriovenous shunt. The second report presents a case of a 41-year-old woman, who felt sudden sharp pain in the neck while skiing. Neurologically, she developed an incomplete spinal cord lesion with quadriparesis with left-sided accentuation of severe intensity and sensation threshold at C1. The MR and MRAG of the cervical spinal cord and the following DSA of vertebral artery detected AVM fed by the left posterior spinal artery. Elective endovascular embolization was indicated and the patient was treated at a specialized institute in France., and T. Andrašinová, B. Adamová, A. Krajina, T. Andrašina
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
27. Symptomatická stenóza jaterní žíly
- Creator:
- Čabelková, Pavla, Krajina, Antonín, Chovanec, Vendelín, Renc, Ondřej, Hůlek, Petr, and Brůha, Radan
- Format:
- print, text, and regular print
- Type:
- model:article, article, Text, kazuistiky, and TEXT
- Subject:
- Buddův-Chiariho syndrom--etiologie--chirurgie--radiografie, vena hepatica--chirurgie--patologie--radiografie, ascites--etiologie, balónková angioplastika--metody, transjugulární intrahepatální portosystémový zkrat--metody, výsledek terapie, pleurální výpotek--etiologie, portální hypertenze--etiologie, lidé, ženské pohlaví, and dospělí
- Language:
- Czech and English
- Description:
- Buddův-Chiariho syndrom je soubor onemocnění s velice heterogenním spektrem příčin vzniku podmíněný blokádou odtoku krve z jater. V tomto kazuistickém sdělení je popsán případ 32leté pacientky se symptomatickou stenózou jaterní žíly idiopatického původu, která byla léčena na našem pracovišti v letech 2014 a 2015. Žena trpěla refrakterním fluidothoraxem, přičemž po neúspěšné diuretické léčbě byla odeslána na angiointervenční oddělení naší nemocnice. Do stenotické pravé jaterní žíly, při hypoplastické střední a levé, byl implantován balonexpandibilní stent. Po 6 měsících bez obtíží se znovu objevila dušnost na podkladě fluidothoraxu, při provedené angiografii byla diagnostikována restenóza ve stentu a byla provedena dilatace balónkem. K dosažení regrese nebylo nutné vytvoření transjugulární portosystémové spojky (TIPS), ale postačilo pouze zavedení balonexpandibilního stentu, což se ukázalo jako dobré řešení pro tento vzácný typ Buddova-Chiariho syndromu., Budd-Chiari syndrome is a group of rare disorders with heterogenous spectrum of causes based on liver outflow blocation. There is a case report of a 32 year old female patient with syptomatic hepatic vein stenosis of idiopathic origin. She was treated in our department in 2014 and 2015. She suffered from refractory hydrothorax and after diuretic therapy was sent to angiointerventional unit of our hospital. The left and middle hepatic veins were hypoplastic. The stenotic right hepatic vein was treated with implantation of balloon expandable stent. After 6 months without symptoms she suffered from shortness of breath with hydro-thorax, on angiography in-stent restenosis was found and balloon dilatation was performed. To maintain regression of symptoms there was no need to perform transjugular portosystemic shunt, placement of balloonexpandable stent was sufficient and it seems to be good solution for this rare type of Budd-Chiari syndrome., Pavla Čabelková, Antonín Krajina, Vendelín Chovanec, Ondřej Renc, Petr Hůlek, Radan Brůha, and Literatura
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
28. Vliv sekundárního zavedení ePTFE potahovaného stentu na udržení průchodnosti TIPS
- Creator:
- Jirkovský, Václav, Fejfar, Tomáš, Šafka, Václav, Hůlek, Petr, Chovanec, Vendelín, Krajina, Antonín, Raupach, Jan, and Lojík, Miroslav
- Type:
- model:article, article, Text, and TEXT
- Subject:
- stenty--statistika a číselné údaje--trendy--využití, transjugulární intrahepatální portosystémový zkrat--metody--využití, portální hypertenze--terapie, angioplastika--metody--statistika a číselné údaje--využití, interpretace statistických dat, výzkum - podpora finanční - jako téma, and lidé
- Language:
- Czech and English
- Description:
- Cíl: Retrospektivně zhodnotit efekt sekundárního zavedení ePTFE potahovaného stentu v léčbě dysfunkce TIPS ve srovnání s dalšími běžnými možnostmi (prostá angioplastika, zavedení dalšího nepotahovaného stentu). Soubor nemocných a metodika: Od začátku roku 2000 do konce roku 2004 byla na našem pracovišti provedena intervence pro dysfunkci TIPS ve 121 případech, kdy byl v době intervence zkrat tvořen pouze nepotahovaným stentem. Dle způsobu intervence byl soubor rozdělen do 4 skupin, a to na intervence s prostou angioplastikou (52 případů, 43,0 %), intervence se zavedením nepotahovaného stentu (35 případů, 28,9 %), intervence se zavedením nededikovaného ePTFE potahovaného stentu (15 případů, 12,4 %) a na intervence se zavedením dedikovaného ePTFE potahovaného stentu (19 případů, 15,7 %). U všech pacientů byla po dané intervenci v pravidelných intervalech sledována další průchodnost zkratu pomocí klinického vyšetření a dopplerovské ultrasonografie, případně i portální venografie. Ve všech 4 skupinách byla zhodnocena primární průchodnost zkratu po dané intervenci pomocí Kaplanovy-Meierovy analýzy. Tyto výsledky primární průchodnosti zkratu po dané intervenci byly vzájemně porovnány pomocí Coxova F-testu a logrank testu. Výsledky: Intervence byla úspěšná ve 120 případech (celková technická úspěšnost všech intervencí byla 99,2 %). Primární průchodnost zkratu po intervenci samotnou angioplastikou byla 49,7 % po 12 měsících a 25,3 % po 24 měsících, po intervenci se zavedením nepotahovaného stentu byla 74,9 % po 12 a 64,9 % po 24 měsících, po intervenci se zavedením nededikovaného ePTFE potahovaného stentu byla 75,2 % po 12 a 64,5 % po 24 měsících a po intervenci se zavedením dedikovaného ePTFE potahovaného stentu byla 88,1 % po 12 a 80,8 % po24 měsících. Statisticky významně lepší průchodnosti zkratu bylo dosaženo ve skupině intervencí se zavedením dedikovaného ePTFE potahovaného stentu a ve skupině se zavedením nepotahovaného stentu oproti skupině intervencí s prostou angioplastikou (p < 0,01). Závěr: Ze všech běžně používaných metod léčebné intervence pro dysfunkci TIPS bylo dosaženo nejlepší následné průchodnosti TIPS po intervenci se zavedením dedikovaného ePTFE potahovaného stentu., Václav Jirkovský, T. Fejfar, V. Šafka, and Lit. 20
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
29. Výsledky studií srovnávajících efekt angioplastik a endarterektomií v léčbě karotických stenóz
- Creator:
- Krajíčková, Dagmar and Krajina, Antonín
- Format:
- print, text, and regular print
- Type:
- model:article, article, Text, přehledy, and TEXT
- Subject:
- lidé, stenóza arteria carotis--chirurgie--terapie, pooperační komplikace, karotická endarterektomie--mortalita--škodlivé účinky, angioplastika--mortalita--škodlivé účinky, randomizované kontrolované studie jako téma, multicentrické studie jako téma, arteria carotis interna, cévní mozková příhoda--epidemiologie--etiologie, infarkt myokardu--epidemiologie--etiologie, odborná způsobilost, karotický stenting, periprocedurální komplikace, studie SAPHIRE, studie EVA-3S, studie SPACE, studie ICS, and studie CREST
- Language:
- Czech and English
- Description:
- Autoři uvádějí systematický přehled velkých randomizovaných studií z posledních let, které srovnávají krátkodobý i dlouhodobý efekt endovaskulární a chirurgické metody při léčbě stenózy odstupu vnitřní karotické tepny. Studie prokázaly podobný pozitivní dlouhotrvající efekt pro obě metody. Vyšší četnost komplikací v periprocedurálním období po angioplastice je způsobena častějšími drobnými neinvalidizujícími mozkovými ischemiemi, endarterektomie má větší riziko srdečního infarktu. Pro úspěch léčby je zásadní zkušenost operatéra a správná indikace nemocného k léčbě. Nemocní by měli být léčeni v centrech, která mají k dispozici obě metody a provádějí je s nízkým počtem komplikací., The authors present a systematic review of recent large randomized studies comparing short and long-term effect of endovascular and surgical treatment of the internal carotid artery stenosis at its origin. The studies showed similar beneficial long-term effect of both methods. Higher rate of complications in angioplasty is caused by minor debilitating ischemic strokes in the periprocedural period while the endarterectomy has higher risk of myocardial infarction. Experience of the operator and appropriate patient indication for therapy are crucial for treatment success. Patients should be treated in centers in which both methods are routinely available with lower rate of complications. Key words: carotid stenting – carotid endarterectomy –randomized study – periprocedural complications – long-term outcomes The authors declare they have no potential conflicts of interest concerning drugs, products, or services used in the study. The Editorial Board declares that the manuscript met the ICMJE “uniform requirements” for biomedical papers., and D. Krajíčková, A. Krajina
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
- « Previous
- Next »
- 1
- 2
- 3