Aim: The principal aim was to establish reference paediatric data for the serum homocysteine levels in Czech children and adolescents. Methods and Results: 144 children either healthy or not sufferig from acute or chronic inflammation, autoimmune disorders including rheumatic diseases, inflammatory musculoskeletal disorders, inflammatory bowel disease, diabetes mellitus, hypercholesterolemia, epilepsy, chronic renal failure, aged 0–19.9 years (0–6.9 years, n = 40; 7–10.9 y, n = 28; 11–15.9 y, n = 45; 16–19.9 y, n = 31) had their blood samples collected and the serum homocysteine level (S-homocysteine) was evaluated by chemiluminescence. A significant age dependence of the S-homocysteine levels was observed (R = 0.35, p < 0.01); with highest values of upper reference range in the 11–15.9 and 16–19.9 years’ group, respectively. Conclusion: The establishment of S-homocysteine reference Czech pediatric values is a potentially useful tool for proper evaluation of elevated homocysteine levels and corresponding risks in childhood., Vladimír Němec, Eva Bočkayová, Štěpán Kutílek, and Literatura 30
Cíl studie: Zavedení nové techniky, kapalinové chromatografie ve spojení s tandemovou hmotnostní spektrometrií do rutinního stanovení hladiny celkového homocysteinu v plazmě. Materiál a metoda: Metodou kapalinové chromatografie ve spojení s tandemovou hmotnostní spektrometrií byly analyzovány vzorky pacientů zaslané do laboratoří Onkologického Centra J. G. Mendela. Výsledky: V pozitivním multiple reaction monitoring módu byl monitorován ion vzniklý rozpadem fragmentu m/z 135,9 → 89,8 pro homocystein a m/z 140 → 90 pro interní standard, homocystein-d4. Vyvinutá LC/MS/MS metoda má následující parametry: retenční čas homocysteinu i homocystinu-d8 1,4 minuty, mez stanovitelnosti 0,5 μmol/l, mez detekce 0,1 μmol/l. Opakovatelnost byla stanovena v sérii 20 měření analýzou 2 kontrolních vzorků, na hladině 8,3 μmol/l byl variační koeficient 0,12 %, na hladině 18,2 μmol/l byla hodnota variačního koeficientu 0,71 %. Závěr: Byla zavedena vysoce selektivní, specifická a časově nenáročná technika vhodná pro rutinní stanovení hladiny celkového homocysteinu v plazmě., Objective: To develop a new LC/MS/MS - based method for routine measurement of total homocysteine in plasma. Material and Method: Patient samples from laboratories of Cancer Centre of J. G. Mendel were analyzed by liquid chromatography with tandem mass spectrometry. Results: Ion transitions m/z 135.9 → 89.8 for homocysteine and m/z 140 → 90 for internal standard – homocysteine-d4 were monitored in the positive multiple reaction-monitoring mode. Our newly developed LC/MS/MS method has the following characteristics: retention time of homocysteine and homocystine-d8 is 1.4 min, limit of quantitation 0.5 μmol/l and limit of detection 0.1 μmol/l. Repeatability was determined by analyzing 2 plasma samples, the variation coefficients obtained were 0.12 % at concentration of 8.3 μmol/l and 0.71 % at concentration of 18.2 μmol/l. Conclusion: The selective, specific and rapid method suitable for routine determination of total homocysteine in plasma was developed., Soňa Humplíková, J. Minář, M. Kučerová, and Lit. 18