Reactive hyperemia (RH) in forearm muscle or skin microcirculation has been considered as a surrogate endpoint in clinical studies of cardiovascular disea e. We evaluated two potential confounders that might limit such use of RH, namely laterality of measurement and intake of non-steroidal anti-inflammatory drugs (NSAIDS). Twenty-three young non-smoking healthy adults were enrolled. In Experiment 1 (n=16), the RH elicited by 3 min of ischemia was recorded in the muscle (strain gauge plethysmography, hand excluded) and skin (laser Doppler imaging) of both forearms. In Experiment 2 (n=7), RH was determined in the dominant forearm only, one hour following oral acetylsalicylic acid (1 g) or placebo. In Experiment 1, peak RH was identical in both forearms, and so were the corresponding durations of responses. RH lasted significantly less in muscle than in skin (p=0.003), a hitherto unrecognized fact. In the skin, acetylsalicylate reduced duration (43 vs. 57.4 s for placebo, p=0.03), without affecting the peak response. In muscle, duration tended to decrease with acetylsalicylate (21.4 vs. 26.0 s with placebo, p=0.06) and the peak increase in blood flow was blunted (27.2 vs. 32.4 ml/min/100 ml tissue with placebo, p=0.003). We conclude that, when using RH as a surrogate endpoint in studies of cardiovascular disease, a confounding by laterality of measurement need not be feared, but NSAIDS may have an influence, although perhaps not on the peak response in the skin., G. Addor, A. Delachaux, B. Dischl, D. Hayoz, L. Liaudet, B. Waeber, F. Feihl., and Obsahuje bibliografii a bibliografické odkazy
The macrophage cell-line J774.E1 and Leishmania m. mexicana infection was used to investigate the uptake of liposomes, which differed in their bulk phospholipid: ester- or ether-analogue of phosphatydilcholine (PC). The receptor-mediated uptake of both species of liposomes, containing native or acetylated LDL as ligands was also evaluated. Uninfected and infected J774.E1 cell-line accumulated more ester- and ether-liposomes alone than mixed type (50:50, ester/ether). The utilization was significantly enhanced when both types of liposomes contained native LDL. The highest uptake was recorded for liposomes bearing acetylated LDL by infected J774.E1 cells. Accumulation of ester- and ether-liposomes with the same ligand was not markedly affected by different chemical nature of PC. Finally, ether-liposomes alone possessed certain activity against Leishmania m. mexicana amastigotes. The results presented here demonstrated the usefulness of ether-liposomes with specific ligands in site-specific delivery of antileishmanial compounds in vitro.
The purpose of this study was to test the hypothesis that more recently developed rubber dam systems (OptraDam ® Plus and OptiDam™) are faster and easier to handle, and that the quality of isolation is not decreased. The rubber dam systems were applied in standard conditions on a dental simulator in several model clinical situations. The time of preparation, application and removal were measured and the quality of isolation was evaluated. The median time of rubber dam placement was 51 s (Q1 = 38 s; Q3 = 79 s). The shortest median time of application was with OptiDam™ (42 s), followed by a conventional rubber dam (53 s), and finally the longest was with OptraDam® Plus (58 s). The median volume of fluid remaining in the isolated space after 5 minutes was 9.5 mL (Q1 = 8 mL; Q3 = 10 mL). The largest median volume of remaining water was with OptiDam™ (10 mL), followed by a conventional rubber dam (9.5 mL) and the least with OptraDam® Plus (8.5 mL). The afore-stated hypothesis about the advantages of modern rubber dam isolation systems was accepted for OptiDam™, but rejected for OptraDam® Plus. The results could contribute to decision-making concerning the choice of rubber dam system. and Martin Kapitán, Zdeňka Šustová, Romana Ivančaková, Jakub Suchánek
This paper pursues the effect of changes in distance and vibration frequency on the vibration velocity amplitude. As an example, we used the vibrating sheet piles at the cons truction of a new multi-functional FEI building on the premises of VŠB - TU Ostrava, at 17 listopadu street. The effect of these changes is monitored both in in-situ measurements and in a simulated real-life situation. The calculation software Plaxis 2D is used for creation of numer ical models. At the close, the results from in-situ measurements are confronted with those achieved from the models., Tomáš Petřík, Eva Hrubešová and Markéta Lednická., and Obsahuje bibliografické odkazy
To determine whether PHEMA [poly(2-hydroxyethylmethacrylate)] is suitable for portal vein embolization in patients scheduled to right hepatectomy and whether it is as effective as the currently used agent (a histoacryl/lipiodol mixture). Two groups of nine patients each scheduled for extended right hepatectomy for primary or secondary hepatic tumor, had right portal vein embolization in an effort to induce future liver remnant (FLR) hypertrophy. One group had embolization with PHEMA, the other one with the histoacryl/lipiodol mixture. In all patients, embolization was performed using the right retrograde transhepatic access. Embolization was technically successful in all 18 patients, with no complication related to the embolization agent. Eight patients of either group developed FLR hypertrophy allowing extended right hepatectomy. Likewise, one patient in each group had recanalization of a portal vein branch. Hist ology showed that both embolization agents reach the periphery of portal vein branches, with PHEMA penetrating somewhat deeper into the periphery. PHEMA has been shown to be an agent suitable for embolization in the portal venous system comparable with existing embolization agent (histoacryl/lipiodol mixture)., J. H. Peregrin, R. Janoušek, D. Kautznerová, M. Oliverius, E. Sticová, M. Přádný, J. Michálek., and Obsahuje bibliografii
The aim of this study was to investigate the effects of troglitazone (TRO) - a new insulin-sensitizing agent - on some metabolic parameters in an experimental model of hypertriglyceridemia and insulin resistance, hereditary hypertriglyceridemic rats, and to compare its effects with those of vitamin E, an antioxidant agent. Three groups of the above rats were fed diets with a high content of sucrose (70 % of energy as sucrose) for four weeks. The first group was supplemented with TRO (120 mg/kg diet), the second one with vitamin E (500 mg/kg diet), and the third group served as the control. Vitamin E supplementation did not lower serum triglycerides (2.42±0.41 vs. 3.39±0.37 mmol/l, N.S.) while TRO did (1.87±0.24 vs. 3.39±0.37 mmol/l, p<0.01). Neither TRO nor vitamin E influenced the serum levels of free fatty acids (FFA). Both drugs influenced the spectrum of fatty acids in serum phospholipids - TRO increased the levels of polyunsaturated fatty acids (PUFA) n-6 (36.04±1.61 vs. 19.65±1.56 mol %, p<0.001), vitamin E increased the levels of PUFA n-3 (13.30±0.87 vs. 6.79±0.87 mol %, p<0.001) and decreased the levels of saturated fatty acids (32.97±0.58 vs. 51.45±4.01 mol %, p<0.01). In conclusion, TRO lowered the level of serum triglycerides but vitamin E did not have this effect in hypertriglyceridemic rats. Compared with TRO, vitamin E had a different effect on the spectrum of fatty acids in serum phospholipids., Š. Chvojková, L. Kazdová, J. Divišová., and Obsahuje bibliografii
The aim of this study was to compare the isolation systems OptraDam® Plus and OptiDam™ with the conventional rubber dam in terms of objective and subjective parameters. The isolation systems were applied during the dental treatment of the patients. The time of preparation, placement, presence and removal were measured and the quality of isolation was evaluated. The median time of rubber dam placement was 76 s (Q1=62 s; Q3=111.25 s). The application time of OptraDam® Plus was significantly longer compared to the other systems (P ® plus. The results presented in this study could guide clinicians for choosing the most appropriate isolation system. and M. Kapitán, T. Suchánková Kleplová, J. Suchánek
We derive a curvature identity that holds on any 6-dimensional Riemannian manifold, from the Chern-Gauss-Bonnet theorem for a 6-dimensional closed Riemannian manifold. Moreover, some applications of the curvature identity are given. We also define a generalization of harmonic manifolds to study the Lichnerowicz conjecture for a harmonic manifold "a harmonic manifold is locally symmetric" and provide another proof of the Lichnerowicz conjecture refined by Ledger for the 4-dimensional case under a slightly more general setting., Yunhee Euh, Jeong Hyeong Park, Kouei Sekigawa., and Obsahuje bibliografii
The correlation between baroreflex sensitivity (BRS) and the spectrum component at a frequency of 0.1 Hz of pulse intervals (PI) and systolic blood pressure (SBP) was studied. SBP and PI of 51 subjects were recorded beat-to-beat at rest (3 min), during exercise (0.5 W/kg of body weight, 9 min), and at rest (6 min) after exercise. BRS was determined by a spectral method (a modified alpha index technique). The subjects were divided into groups according to the spectral amplitude of SBP at a frequency of 0.1 Hz. The following limits of amplitude (in mm Hg) were used: very high ≥ 5.4 (VH); high 5.4 > H ≥ 3 (H); medium 3 > M ≥ 2 (M), low < 2 (L). We analyzed the relationships between 0.1 Hz variability in PI and BRS at rest, during the exercise and during recovery in subgroups VH, H, M, L. The 0.1 Hz variability of PI increased significantly with increasing BRS in each of the groups with identical 0.1 Hz variability in SBP. This relationship was shifted to the lower values of PI variability at the same BRS with a decrease in SBP variability. The primary SBP variability increased during exercise. The interrelationship between the variability of SBP, PI and BRS was identical at rest and during exercise. A causal interrelationship between the 0.1 Hz variability of SBP and PI, and BRS was shown. During exercise, the increasing primary variability in SBP due to sympathetic activation was present, but it did not change the relationship between variability in pulse intervals and BRS., N. Honzíková, A. Krtička, Z. Nováková, E. Závodná., and Obsahuje bibliografii
The absolute gravity measurements are an important tool for reliable monitoring geodynamic phenomena. Based on the experience with the absolute gravimeter FG5#215 (gravimeter of the Center for Earth Dynamics Research), the accuracy of FG5 absolute gravimeters is presented in this study. The instrumental reproducibility of this meter is characterized by the value of 0.7 μGal. Discussed are important environmental effects on gravity measurements, such as atmospheric and hydrological effects, understanding of which is necessary for correct and reliable interpretation of the repeated absolute gravity measurements in geodynamics., Vojtech Pálinkáš, Jakub Kostelecký and Jaroslav Šimek., and Obsahuje bibliografii