The article presents a method of pH measurement of aqueous humour during cataract surgery. The method uses a fiber optic sensor with immobilized fluorescent dye. A functional sample of fiber optic pH meter was used for measurements, developed in cooperation of the Institute of Photonics and Electronics, Academy of Sciences of the Czech Republic, v.v.i., Safibra, s.r.o. and SQS Vláknová optika a.s. The accuracy of determined pH values was 0.04 pH unit or better. and V článku je prezentována metodika měření nitrooční tekutiny během operace katarakty (šedého zákalu), která je založena na použití vláknově optického senzoru s imobilizovaným fluorescenčním barvivem. K měření byl použit funkční vzorek vláknově optického pH metru vyvinutý ve spolupráci Ústavu fotoniky a elektroniky, Akademie věd ČR, v.v.i., Safibra, s.r.o. a SQS Vláknová optika a.s. Hodnoty pH byly stanoveny s přesností 0,04 nebo lepší.
Fat-enriched diet is strongly associated with cataract development. Laurus nobilis shows antioxidant activity. Herein we evaluated the effect of Laurus nobilis oral administration on the blood and lenses antioxidant activity in rabbits under fat-enriched diet. Sixty rabbits divided into 4 groups were used. One group represented the control (N-CTR). The second group (P-CTR) fed a diet supplemented with 2.5 % of pig fat; the third group (EXP1) received a diet supplemented with 2.5 % of pig fat and 1 g/kg of dried-bay leaves; the fourth group (EXP2) was treated with dried-bay leaves at the rate of 1 g/kg of feed. At baseline and at the end of the study (56 days) the following blood parameters were determined: thiobarbituric acid reactive substances (TBARS), reactive oxygen metabolites (ROMs), total phenols, superoxide dismutase (SOD), oxygen radical absorbance capacity (ORACpca), ferric ion reducing antioxidant power (FRAP), retinol and alfa-tocopherol. At the end of the follow-up, the eyes were enucleated and the antioxidant profile, such as total antioxidant activity (TAC), TBARS, retinol and alfa-tocopherol of lenses was evaluated. Plasma ROMs and TBARS levels were statistically lower in the groups receiving bay leaves integration. A significant increase of plasma retinol, FRAP and ORACpca levels was found in EXP1 and EXP2 groups, whereas plasma alfa-tocopherol resulted statistically higher only in EXP2 group. Bay leaves supplementation enhanced TAC, retinol and alfa-tocopherol in rabbit lens, particularly in EXP2 group; whereas lenses TBARS levels significantly decreased in both treated groups. These findings demonstrate that Laurus nobilis oral administration exerts a protective effect on the risk of cataract development in rabbits under fat-enriched diet., D. Casamassima, F. Chiosi, F. Vizzarri, M. Palazzo, C. Costagliola., and Obsahuje bibliografii
The cataract is the physiological process of the aging which is treated by the ophthalmological surgeon. The surgeon removes the opacity mass from the human lens and insert the intraocular lens (IOL) with the specific dioptric power. The implant dioptric power calculation is realized by formulas based on the statistical principles. The accuracy of these formulas is good in the biometric normal eye (the axial length of the eye 22 to 24mm, keratometry of the cornea around 43 D). However, the dioptric power calculation of the implant in the non-biometric standard eye leads to the unexpected postoperative axial refraction. The new proposed method based on the ray tracing allows the computation with the higher accuracy. The accuracy of this method was confirmed by the clinical study. and Vznik katarakty, neboli šedého zákalu, je fyziologickým projevem stárnutí a běžně se dnes řeší chirurgickým výkonem. V rámci tohoto výkonu jsou z lidské čočky odsáty zkalené čočkové hmoty a do oka je vložena nitrooční čočka (IOL) o jmenovité dioptrické hodnotě, která má nahradit chybějící dioptrie oka. Výpočet optické mohutnosti nitrooční čočky je prováděn léty ověřenými vzorci. Tyto vzorce z velké části čerpají ze statistického základu a vedou k velmi dobré prediktibilitě v oblasti statisticky normálních očí, tj. axiální délka oka 22 až 24mm, keratometrie rohovky okolo 43 D. Výpočet optické mohutnosti IOL v případě očí s nestandardními biometrickými hodnotami není vždy zcela přesný a setkáváme se s nežádoucí pooperační refrakcí. Metoda ray tracing úspěšně odbourává statistický základ výpočtu. Tato metoda se snaží velmi věrně napodobit šíření světla a je vhodná k použití na jakékoliv biometricky rozmanité oko. Výpočet IOL postavený na metodě ray tracing poskytuje v oblasti nestandardních očí výsledky, které jsou přesnější než konvenčně používané vzorce. Tento závěr byl učiněn po klinické studii provedené na 6 očích.