Bio-degradable stents are be made of different synthetic polymers (like polylactide or polyglycolide) or their co-polymers (polydioxanone). They can be used for treating benign stenoses of the small and large intestine, particularly in Crohn’s disease. Endoscopic introduction of bio-degradable stents into small and large intestinal stenoses is feasible and relatively simple. Initial results are encouraging and the complication rate is low. However, there are still some difficulties that need to be overcome. The rate of early stent migration is still rather high (up to one third of patients). This might be solved by changes in the shape or rigidity of the stents as well as by further improvement in the design. Proof of long-term efficacy and safety requires further studies., Stanislav Rejchrt, Jan Bureš, Jan Brožík, Marcela Kopáčová, and Literatura 52
The pilot study deals with the clinical results of the regenerative therapeutical method in intraosseous periodontal defects done by surgical augmentation procedure using a material of a new generation prepared on the basis of a bioactive glass. A group of 10 individuals were treated properly for chronic periodontitis. Some of treated infraalveolar periodontal lesions, both periodontal pockets and interradicular defects, persisted or recurred in posterior teeth. In order to eliminate them they were indicated for advanced periodontal surgery or regenerative surgical therapy stimulating healing processes of supportive tissues, mostly alveolar bone around treated teeth. Relevant clinical parameters, i. e. values of the pocket depth, gingival recession, and loss of attachment were evaluated before and after the periodontal surgery and compared with each other. The therapy led to significant improvement of clinical parameters in terms of the reduction of pocket depth and loss of attachment values. and R. Slezák, V. Paulusová
Cíl: Cílem sdělení je připomenout možná úskalí paralelního hodnocení výsledků elektroforézy séra a sérových hladin volných lehkých řetězců (VLŘ) imunoglobulinu. Stanovení sérových hladin VLŘ se v posledních letech stalo nedílnou součástí algoritmu vyšetření využívaných v diagnostice a monitorování nemocných s monoklonální gamapatií. Zkušenosti mnoha pracovišť a následně publikovaná doporučení napomáhají vhodné indikaci vyšetření a interpretaci nálezů, avšak v každodenní praxi se často setkáváme s výsledky diskrepantními či atypickými, což si vyžaduje obezřetnou interpretaci, ověření stanovení a úzkou spolupráci zúčastněných odborníků., Aim: The aim of the presented paper is to remind of possible pitfalls of parallel assessment of serum electrophoresis and serum free light chain levels (FLC) of the immunoglobulins. Evaluation of serum levels of FLC has become an inherent part of the algorithm in the diagnostics and monitoring of patients with monoclonal gammopathy. Experience from several departments followed by published recommendations help to determine appropriate indication and interpretation of the results. Everyday practice, however, brings also dissimilar or atypical results that need a careful interpretation, verification of the results and close cooperation of participating specialists., Pika T., Lochman P., Minařík J., Bačovský J., Ščudla V., and Literatura 33
Cíl studie: Měření koncentrací albuminu a imunoglobulinů v likvoru a v séru slouží v likvorové diagnostice k výpočtu intrathékální syntézy imunoglobulinů. Předpokládá se, že hodnotu kvocientu, tj. poměru koncentrací daného proteinu v likvoru a v séru, lze považovat za nezávislou na použité metodě, pokud je párový vzorek likvoru a séra analyzován současně na jedné (likvorové) kalibrační křivce. Pozorované diskrepance mezi likvorovými (ale nikoliv sérovými) koncentracemi IgM stanovenými nefelometricky na analyzátoru Immage a home-made sendvičovou ELISA metodou nás vedly k provedení rozsáhlejší studie srovnávající různé metody stanovení IgM v likvoru a séru. Typ studie: Porovnání výsledků různých metod používaných pro kvantifikaci IgM v likvoru. Materiál a metody: Byly srovnány výsledky stanovení koncentrací IgM získané na nefelometrech Immage, Immage 800, BN II, BN ProSpec a metodou ELISA. Vedle likvorových a sérových koncentrací byly srovnány i kvocienty likvor/sérum a výsledek výpočtu intrathékální syntézy podle Reiberova vztahu. Výsledky byly vyhodnoceny metodami Passing-Bablokovy regrese a grafu dle Blanda a Altmana s využitím statistického programu MedCalc. Výsledky: Zjistili jsme výrazné rozdíly v likvorových koncentracích IgM stanovených nefelometricky na analyzátorech Immage oproti nefelometrickému stanovení na analyzátorech řady BN a „home-made“ sendvičové ELISA metodě, které poskytly významně nižší hodnoty. Hodnoty získané ELISA metodou byly v dobré shodě s hodnotami získanými na analyzátorech řady BN. Sérové koncentrace IgM byly poněkud vyšší při použití ELISA metody. Nebyl zjištěn významný rozdíl mezi hodnotami sérových koncentrací a kvocientů likvor/sérum získanými analýzou séra na likvorové versus sérové kalibrační křivce. Hodnoty kvocientu likvor/sérum byly významně vyšší v případě stanovení na analyzátorech Immage oproti hodnotám získaným analýzou na nefelometrech řady BN i ELISA metodou. V důsledku toho byla z dat získaných na analyzátorech Immage vypočtena intrathékální syntéza IgM u 13 ze 71 vzorků, u kterých nebyla zjištěna z dat získaných na analyzátoru BN ProSpec ani ELISA metodou; u 8 z nich bylo možno považovat vypočtenou intrathékální syntézu za klinicky významnou (intrathékální frakce >10 %). Závěr: Kvocient likvor/sérum je pro IgM jednoznačně závislý na použité metodě stanovení a v některých případech může dojít i k rozdílnému hodnocení přítomnosti intrathékální syntézy IgM. Dokud se nepodaří příčinu tak výrazně odlišných výsledků koncentrace IgM v likvoru objasnit a odstranit, je žádoucí při měření na analyzátoru Immage hodnotit vypočtenou intrathékální syntézu IgM velmi opatrně a v kontextu celého likvorového nálezu. ELISA metoda je finančně nenákladná, vyžaduje minimální množství vzorku a jeví se jako jediná schopná kvantifikovat IgM prakticky v každém vzorku. Její použití v rutinní praxi je však limitováno vyššími nároky na manuální zpracování, jeví se však jako výhodná metoda minimálně pro experimentální studie, např. sledování rozložení likvorových koncentrací IgM v populaci., Objective: Quantitation of albumin and immunoglobulins in CSF and serum serves the purpose of calculation of intrathecal immunoglobulin synthesis. Quotient, i.e., concentration ratio of particular protein in CSF and serum, is assumed to be method-independent value, provided that paired CSF and serum sample is analyzed in parallel using one (CSF) calibration curve. We have observed that CSF (but not serum) IgM concentrations determined by nephelometry on Immage analyzer and by home-made sandwich ELISA were largely discrepant. This has lead us to perform a larger study comparing various methods of IgM determination in CSF and serum. Design: Comparison of various methods used for IgM quantitation in cerebrospinal fluid. Materials and Methods: Results of IgM determination on nephelometers Immage, Immage 800, BN II, and BN ProSpec, as well as by ELISA method, have been compared. Beside CSF and serum values, CSF/serum quotients and results of calculated intrathecal IgM synthesis according to Reiber´s formula have been compared. Results have been evaluated by means of Passing-Bablok regression and Bland and Altman plots, using MedCalc software. Results: We have found significant differences between CSF IgM concentrations determined by rate nephelometry on Immage analyzers and end-point nephelometry on BN analyzers or ELISA, the latter two giving significantly lower values. CSF IgM concentrations determined by ELISA were in good agreement with those determined on BN analyzers. Serum IgM concentrations were slightly higher using ELISA than using either nephelometric system. We have found no significant difference in either serum IgM or CSF/serum IgM quotient between serum analysis on CSF versus serum calibration curve. IgM quotient values were significantly higher using Immage analyzers than using either BN analyzers or ELISA method. As a consequence, intrathecal IgM synthesis, based on the Immage data, was calculated in 13 of 71 samples considered negative if data of BN analyzer or ELISA were used; in 8 of these samples, intrathecal IgM synthesis could be considered as clinically significant (intrathecal fraction > 10 %). Conclusions: CSF/serum IgM quotient is far from to be method-independent; in some cases, discrepant conclusion regarding the presence of intrathecal IgM synthesis can be obtained. Until the cause of this discrepancy is found and removed, the presence of intrathecal IgM synthesis should be judged very carefully and in the context of other CSF findings when using the Immage analyzer for measurement. ELISA method is inexpensive, requires very low amount of the sample, and is the only method able to quantify IgM in almost every CSF sample. Its use in routine practice is, however, limited by higher requirements for manual work. Nevertheless, it should be used at least in experimental studies, i.e. for the purpose of the determination of distribution of CSF IgM concentration within a population., Zeman D., Kušnierová P., Gottwaldová J., Kloudová A., Lochman I., Ženková J., Švagera Z., Bartoš V., Všianský F., and Literatura 12
Epilepsia je chronické ochorenie, ktoré je často sprevádzané psychiatrickou komorbiditou. Najčastejšou z nich je depresia, ktorá je sprevádzaná subsyndromálnymi, atypickými a chronifikovanými príznakmi depresie. Incidencia depresie je u pacientov s epilepsiou vyššia ako u iných neurologických alebo chronických ochorení. Psychopatológia spojená s epilepsiou obťažuje pacienta častokrát viac ako samotné ochorenie. Cieľom práce je prezentácia a analýza kazuistiky 37-ročného muža s diagnózou epilepsie so sprievodnou psychiatrickou symptomatikou, ktorá znížila kvalitu jeho života oveľa viac ako samotné neurologické ochorenie. V kazuistike popisujeme klinické symptómy neuropsychiatrického ochorenia – epilepsie ako aj životné udalosti, ktoré sú u každého pacienta jedinečné a majú závažný vplyv na priebeh a liečbu epilepsie., Epilepsy is a chronic disease that is often accompanied by psychiatric comorbidity. The most frequent of them is depression accompanied by subsyndromic, chronic and atypical symptoms of depression. The incidence of depression in patients with epilepsy is higher than in other neurological or chronic diseases. Psychopathology associated with epilepsy often bothers the patient more than the disease itself. The aim of this work is to present and analyze a case report of a 37‑year‑old man diagnosed with epilepsy and associated psychiatric symptomatology that reduced his quality of life much more than the neurological disease itself. In this case report, we describe clinical symptoms of neuropsychiatric disease – epilepsy as well as life events that are unique to each patient and have a significant impact on the course and treatment of epilepsy. Key words: epilepsy – anxiety – depression – personality changes The authors declare they have no potential conflicts of interest concerning drugs, products, or services used in the study. The Editorial Board declares that the manuscript met the ICMJE “uniform requirements” for biomedical papers., and J. Vančíková, A. Bednářová
Přehled pojednává o problematice věnované základům hmotnostní spektrometrie. Jsou zde vysvětleny význam a principy fungování jednotlivých částí hmotnostních spektrometrů. Dále jsou uvedena instrumentální uspořádání, která jsou v současnosti používaná pro analýzu biologických materiálů., The overview is focused on basics of mass spectrometry. Importance and principles of mass spectrometry parts are explained. Different mass spectrometry instruments, which are used for analysis of biological materials, are introduced., Friedecký D., Lemr K., and Literatura 4